Embroidery Settings
Embroidery Settings 1
Embroidery Settings 2
Opening Setup Program
press the external Setup button
menu appears
•
touch «Embroidery Settings»
the screen «Embroidery Settings 1» appears for adjusting the
•
embroidery hoop
«Adjust Reference Position» calibrates the needle to the center of
the embroidery hoop. Adjusting can only be activated if the
embroidery module and the oval embroidery hoop are attached.
It is only necessary to adjust the Reference Position once as the
same setting changes will apply to all the hoops.
insert the embroidery template into the hoop
touch «Check»
the hoop position is read and the needle positioned in the
•
middle (the needle should now be positioned exactly over the
center point of the template)
if it is not, adjust with the arrows
touch «OK»
the adjustment will be saved, the screen display closes and the
•
menu appears
touch «To Next Page»
the screen «Embroidery Settings 2» appears
•
Motor Speed
touching «+» or «–» changes the basic settings of the speed by
•
10 stitches
the number in the bar reflects the stitches per minute
•
any change of the speed affects all 4 speeds (1/4 – 4/4), i.e.
•
slower or faster at all four levels
Auto Thread Cutter
when the bar is active (blue) the upper thread and bobbin
•
thread are automatically cut
when the bar is inactive (x) the Automatic Thread Cutter is off
•
touching the bar «Auto Thread Cutter» activates or deactivates
the function
Thread Tension Correction
touching «+» or «–» changes the basic setting (0) of the upper
Thread Tension by plus or minus 20%
0 = basic settings (factory settings)
1 = + 10%
2 = + 20%
-1 = - 10%
-2 = - 20%
this correction fine tunes the basic tension setting on your
•
sewing computer, which may be affected by variables such as
thread weight, etc.
the number in the bar and the blue background of the «+» and
•
«–» reflect the changes
the «Default» on-screen button returns you to the basic settings
•
the tension alteration affects all motifs and remains saved when
•
the embroidery computer is turned off («0»)
167
Setup Program