B-14 Compaq ProLiant Clusters HA/F100 and HA/F200 Administrator Guide
Table B-3
Error Messages
Could not load resource DLL.
Logical disk could not be
reached in the following
RA4000: <xxxxxx>.
The lock could not be set.
The loop has been locked by
another application. Redundancy
Manager is running in Read Only
mode.
There was an error attempting
to shut down Windows. Please
close all applications and shut
down now.
NT Event Log states:
The Host Bus Adapter in slot %1
has averaged more than %2
Elastic Store Errors for the last
five seconds. The loop has
become unstable. The adapter
has been taken offline.
continued
Message
This message signifies that the
file containing the configuration
utility resources could not be
loaded.
This message indicates that
Redundancy Manager found an
RA4000 with no drives in it. A
damaged RA4000 or a bad
connection could cause this.
This message informs you that
the array controller board is in
an unknown state that caused a
failed connection to the array
controller.
This message informs you that
another application has issued a
lock management command to
an array controller. The lock
management command only
allows you to view the data.
This message signifies that an
error occurred while shutting
down Windows.
GBIC laser has malfunctioned.
Description
Action
Reload Redundancy Manager
from the CD.
Check the RA4000 and all
connections.
No action needed to view the
data.
To configure the data, check the
array controller and all physical
connections.
No action needed to view the
data.
To configure the data, close the
other application to unlock the
array controller. If the lock has
expired, Redundancy Manager
allows you to override the lock
and take control of the array
controller.
Close all applications and shut
down your computer
immediately.
Refer to the Compaq
StorageWorks RAID Array 4000
User Guide 's "Replacing GBICs"
chapter for instructions about
how to replace a GBIC.
continued

Advertisement

Table of Contents
loading

Table of Contents