Table 1-2. System Messages (continued)
Message
BIOS Update
Attempt Failed!
Caution!
NVRAM_CLR jumper
is installed on
system board
CPU set to
minimum
frequency.
CPU x installed
with no memory.
CPUs with
different cache
sizes detected.
CPUs with
different core
sizes detected!
System halted
CPUs with
different
logical
processors
detected! System
halted
CPUs with
different power
rating detected!
System halted
40
About Your System
Causes
Remote BIOS update
attempt failed.
NVRAM_CLR jumper is
installed in the clear setting.
CMOS has been cleared.
The processor speed may be
intentionally set lower for
power conservation.
Memory modules are
required but not installed in
the indicated processor's
memory slots.
Mismatched processors have
been installed in the system.
Corrective Actions
Retry the BIOS update. If
problem persists, see
"Getting Help."
Move the NVRAM_CLR
jumper to the default
position (pins 3 and 5). See
Figure 6-1 for jumper
location. Restart the system
and re-enter the BIOS
settings. See "Using the
System Setup Program and
UEFI Boot Manager."
If not an intentional setting,
check any other system
messages for possible causes.
Install memory modules for
the processor. See "System
Memory."
Ensure that all processors
have the same cache size,
number of cores and logical
processors, and power rating.
Ensure that the processors
are properly installed. See
"Processors."