Dell PowerEdge R710 Series Hardware Owner's Manual page 26

Dell server hardware owner's manual
Hide thumbs Also See for PowerEdge R710 Series:
Table of Contents

Advertisement

Table 1-1. LCD Status Messages (continued)
Code
Text
E1313 Fan
redundancy
lost. Check
fans.
E1410 System Fatal
Error
detected.
E1414 CPU # temp
exceeding
range. Check
CPU heatsink.
E1418 CPU # not
detected.
Check CPU is
seated
properly.
E141C Unsupported
CPU configur-
ation. Check
CPU or BIOS
revision.
E141F CPU #
protocol
error. Power
cycle AC.
26
About Your System
Cause
The system is no longer fan
redundant. Another fan
failure would put the
system at risk of over-
heating.
A fatal system error has
been detected.
Specified processor is out of
acceptable temperature
range.
Specified processor is
missing or bad, and the
system is in an unsupported
configuration.
Processors are in an
unsupported configuration.
The system BIOS has
reported a processor
protocol error.
Corrective Actions
Check LCD for additional
scrolling messages. See
"Troubleshooting a Fan."
Check LCD for additional
scrolling messages.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Ensure that the processor
heat sinks are properly
installed. See
"Troubleshooting the
Processor(s)" and
"Troubleshooting System
Cooling Problems."
Ensure that the specified
processor is properly
installed. See
"Troubleshooting the
Processor(s)."
Ensure that your
processors match and
conform to the type
described in the processor
technical specifications
outlined in your system's
Getting Started Guide.
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."

Hide quick links: