Table 1-1. LCD Status Messages (continued)
Code
Text
E1420 CPU Bus
parity error.
Power cycle
AC.
E1422 CPU # machine
check error.
Power cycle
AC.
E1610 Power Supply
# (### W)
missing.
Check power
supply.
E1614 Power Supply
# (### W)
error. Check
power supply.
E1618 Predictive
failure on
Power Supply
# (### W).
Check PSU.
E161C Power Supply
# (### W)
lost AC
power. Check
PSU cables.
Cause
The system BIOS has
reported a processor bus
parity error.
The system BIOS has
reported a machine check
error.
Specified power supply was
removed or is missing from
the system.
Specified power supply has
failed.
A power supply fan failure,
an over-temperature
condition, or power supply
communication error has
caused the predictive
warning of an impending
power supply failure.
Specified power supply is
attached to the system, but
it has lost its AC input.
Corrective Actions
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Getting Help."
See "Troubleshooting
Power Supplies."
See "Troubleshooting
Power Supplies
See "Troubleshooting
Power Supplies."
Check the AC power
source for the specified
power supply. If the
problem persists, see
"Troubleshooting Power
Supplies."