Table 1-1. LCD Status Messages (continued)
Code
Text
E2022 General
failure
during POST.
Check screen
message.
E2023 BIOS unable
to mirror
memory. Check
DIMMs.
E2110 Multibit
Error on DIMM
##. Reseat
DIMM.
E2111 SBE log
disabled on
DIMM ##.
Reseat DIMM.
E2113 Mem mirror
OFF on DIMM
## & ##.
Power cycle
AC.
I1910 Intrusion
detected.
Check chassis
cover.
Cause
General failure after video. Check screen for specific
The system BIOS could not
enable memory mirroring
because of a faulty memory
module or an invalid
memory configuration.
The memory module in slot
"##" has had a multi-bit
error (MBE).
The system BIOS has
disabled memory single-bit
error (SBE) logging and will
not log any more SBEs until
the system is rebooted.
"##" represents the
memory module implicated
by the BIOS.
The system BIOS has
disabled memory mirroring
because it has determined
one half of the mirror has
had too many errors. "##
& ##" represents the
memory module pair
implicated by the BIOS.
System cover has been
removed.
Corrective Actions
error messages.
See "Troubleshooting
System Memory."
See "Troubleshooting
System Memory."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
Remove AC power to the
system for 10 seconds and
restart the system.
If the problem persists,
see "Troubleshooting
System Memory."
Information only.
About Your System