Elapsed Time: f4

Performance Characteristics
Accuracy of measurement
Measurement range
Response time of HOLD input
Recovery time (T
)
R
ON/OFF pulse width
Response time
Relay output
Comparative output 25 ms max.
BCD output
---
Linear output
---
Response time of HOLD
Input
Recovery Time (T
)
R
Measurement starts
INA
Comparative output
Delay in comparative outputs
HOLD input
Acceptance of HOLD input
±
±0.08 rdg
1 digit (ambient temperature: 23°C
10 ms to 3200 s
20 ms max.
20 ms min.
Sensor with transistor output: 9
Sensor with relay output: 15 ms min.
Transistor
output
20 ms max.
35 ms max.
---
Refer to page 93.
---
---
The response time of the HOLD input is the time required for the K3NP to
accept HOLD input after the HOLD input turns ON. This is illustrated in the
following diagram.
Recovery time is the period required for the K3NP to become ready for the
next measuring operation after a measuring operation is completed. For tran-
sistor output Models, comparative output remains ON during recovery time.
For other models, comparative output requires more time to turn ON. When
the comparative output terminals of the output board and the HOLD input
terminals are connected, set a sufficient recovery period, considering the re-
sponse time of the HOLD input. This is illustrated in the following diagram.
Measurement completed
T
1
Recovery time (20 ms min.)
m
s min.
Output configuration
BCD and
Linear and
transistor output
transistor output
35 ms max.
---
40 ms max.
Response time of HOLD input
(20 ms max.)
Section 3-4
±
5°C)
Communication
and transistor
output
20 ms max.
---
---
29