External Input Signals

SETTING
EXAMPLE
1, 2, 3...
5-3

External Input Signals

5-3-1 Bank Selection

84
1. The process value 401 is displayed.
Set Value LED Display Model
2. Press the Escape Key to display the maximum value 1024 and light the MAX
indicator.
Set Value LED Display Model
3. Press the RESET/TEACH Key to set the maximum and minimum values to
the process value 401.
Set Value LED Display Model
4. Press the Escape Key to check that the minimum value is set to 401.
Set Value LED Display Model
· The K3NP uses BANK1 and BANK2 signals to select the setting value, pres-
caling value, and decimal point position of the bank 1, 2, 3, or 4.
Refer to the following for the relationship between bank input signals and bank
numbers.
Control input
Bank no.
BANK 1
1
OFF
2
ON
3
OFF
4
ON
Note If the prescaling bank is set to OFF, the pscl prescaling value for each bank will
be fixed.
· When a bank is selected, the corresponding BANK indicator 1, 2, 3, or 4 will be
lit.
Basic Model
Basic Model
Basic Model
Basic Model
Comparative set value
p
BANK 2
OFF
sU1.**
OFF
sU2.**
ON
sU3.**
ON
sU4.**
Section 5-3
Prescaling value
g
ps1.**
ps2.**
ps3.**
ps4.**