Parameter List
Vari-
CompoWay/F
Modbus
able
Category
Add-
Address
type
ress
DA
Can be
0100
F000
(9A)
changed
0101
F001
during
V1.1
opera-
0102
F002
tion.
0103
F003
0104
F004
0105
F005
0106
F006
0107
F007
0108
F008
0109
F009
0140
F040
0141
F041
0142
F042
0143
F043
0144
F044
0145
F045
0146
F046
0154
F054
0180
F080
0181
F081
0184
F084
0185
F085
0186
F086
0187
F087
0188
F088
0189
F089
018A
F08A
018B
F08B
018C
F08C
018D
F08D
018E
F08E
018F
F08F
0190
F090
0191
F091
0192
F092
0193
F093
0194
F094
0195
F095
Not used.
0200
F100
0300
F200
0400
F300
246
Parameter name
G3PW1-Internal Duty Setting
G3PW1-Base-up Value
G3PW1-Soft-start Up Time
G3PW1-Soft-start Down Time
G3PW1-Output Upper Limit
G3PW1-Output Lower Limit
G3PW1-Heater Burnout Threshold
G3PW1-Heater Characteristic Resistance for
Phase Control
G3PW1-Heater Characteristic Resistance for
Optimum Cycle Control
G3PW1-Heater Burnout Detection Lower
Limit
G3PW1-Input Monitor
G3PW1-Duty Monitor
G3PW1-Output Monitor
G3PW1-Phase Angle Monitor
G3PW1-Current Monitor
G3PW1-Total Run Time Monitor
G3PW1-Status
Version
G3PW1-Send Wait Time
G3PW1-Communications Timeout Time
G3PW1-Communications Main Setting Num-
ber
G3PW1-External Duty Input Enable/Disable
G3PW1-Output Mode Selection
G3PW1-Input Digital Filter Time Constant
G3PW1-Input Signal Type
G3PW1-Main Setting Automatic Input Selec-
tion
G3PW1-Main Setting Manual Input Selection
G3PW1-Control Method Default
G3PW1-Main Setting Automatic/Manual
Default
G3PW1-Number of Alarms for Heater Burnout
Detection
G3PW1-Load Current Upper Limit
G3PW1-Event Input Assignment
G3PW1-Alarm Output Open in Alarm
G3PW1-Heater Burnout Alarm Operation
G3PW1-Total Run Time Exceeded Alarm
Operation
G3PW1-Total Run Time Alarm Set Value
G3PW1-External Input Range Alarm Opera-
tion
G3PW1-External Duty Input Alarm Operation
G3PW2 - Internal Duty Setting
G3PW3 - Internal Duty Setting
G3PW4 - Internal Duty Setting
Setting (monitor) range
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E7 (0.0 to 99.9)
H' 00000000 to H' 000003E7 (0.0 to 99.9)
H' 00000001 to H' 000003E8 (0.1 to 100.0)
H' 00000000 to H' 000003E7 (0.0 to 99.9)
H' 00000000 to H' 00000064 (1 100)
H' 00000000 to H' 00000064 (1 to 100)
H' 00000000 to H' 000003E7 (0.0 to 99.9)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000002EE (0.0 to 75.0)
H' 00000000 to H' 000003E7 (0.0 to 99.9)
---
---
H' 00000000 to H' 00000063 (0 to 99)
H' 00000000 to H' 000003E7 (0 to 999)
H'00000000: Automatic Assignment (0)
H'00000001: EJ1 CH1 Control output (heating) (1)
H'00000002: EJ1 CH2 Control output (heating) (2)
H'00000003: EJ1 CH3 Control output (heating) (3)
H'00000004: EJ1 CH4 Control output (heating) (4)
H'00000005: EJ1 CH1 Control output (cooling) (5)
H'00000006: EJ1 CH2 Control output (cooling) (6)
H'00000007: EJ1 CH3 Control output (cooling) (7)
H'00000008: EJ1 CH4 Control output (cooling) (8)
H' 00000000: Disabled (0)
H' 00000001: Enabled (1)
H' 00000000: Proportional to Phase Angle
(for G3PX Compatibility) (0)
H' 00000001: Proportional to Square Voltage (1)
H' 00000002: Proportional to Voltage (2)
H' 00000003: Constant Current (3)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000: Linear Input (0)
H' 00000001: Voltage ON/OFF Input (1)
H' 00000000: 4 to 20 mA or 1 to 5 V (0)
H' 00000001: Communications (1)
H' 00000000: External Adjuster Input (0)
H' 00000001: Key Input (1)
H' 00000000: Phase Control (0)
H' 00000001: Optimum cycle control (1)
H' 00000000: Automatic (0)
H' 00000001: Manual (1)
H' 00000000 to H' 000003E7 (0 to 999)
H' 00000000 to H' 00000294 (0.0 to 66.0)
H' 00000000: No Assignment (0)
H' 00000001: Control Method Selection (1)
H' 00000002: Main Setting Automatic/Manual
Selection (2)
H' 00000000: Close in alarm (0)
H' 00000001: Open in alarm (1)
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
H' 00000000 to H' 000003E7 (0 to 99.9)
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
H' 00000000: Disable (0)
H' 00000001: Alarm Level 1 (1)
H' 00000002: Alarm Level 2 (2)
The rest are the same as the G3PW1.
Appendix
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
HFU
TC2
0.0
%
NUM
---
0.0
%
NUM
---
0.5
s
NUM
---
0.0
s
NUM
---
100.0 %
NUM
---
0.0
%
NUM
---
100
%
NUM
---
100
%
NUM
---
0.0
W
NUM
---
0.0
%
NUM
---
0.0
%
NUM
---
0.0
%
NUM
---
NUM
---
0.0
%
0.0
%
NUM
---
0.0
A
NUM
---
0.0
kh
NUM
---
---
---
NUM
---
NUM
---
---
---
1
ms
NUM
---
0
s
NUM
---
0
---
NUM
---
NUM
---
0
---
NUM
---
0
---
0.0
ms
NUM
---
0
---
NUM
---
0
---
NUM
---
0
---
NUM
---
0
---
NUM
---
0
---
NUM
---
NUM
---
150
Times
0.0
A
NUM
---
NUM
---
0
---
1
---
NUM
---
0
---
NUM
---
0
---
NUM
---
0.0
kh
NUM
---
NUM
---
1
---
NUM
---
1
---