Omron EJ1 User Manual page 266

Modular temperature controllers
Hide thumbs Also See for EJ1:
Table of Contents

Advertisement

Parameter List
Vari-
CompoWay/F
Modbus
able
Category
Add-
Address
type
ress
D5
Can be
0100
02E0
(95)
changed
0101
02E1
during
operation.
0102
02E2
0103
02E3
0104
02E4
0105
02E5
0106
02E6
Not used.
0109
02E9
010A 02EA
010B 02EB
010C 02EC
010D 02ED
010E 02EE
010F
02EF
0110
02F0
0111
02F1
0112
02F2
0113
02F3
0114
02F4
Not used.
0200
04E0
0300
06E0
0400
08E0
Note
(1) The decimal point position is determined by the sensor selection.
(2) The decimal point position is determined by the sensor selection. In this case, however, the 0 (****)
decimal point position setting will be treated as a setting of 1 (***.*).
Vari-
CompoWay/F
Modbus
able
Category
Add-
Address
type
ress
D6
Can be
0100
0300
(96)
changed
0101
0301
during
operation.
0102
0302
Not used.
0200
0500
Parameter name
Input Digital Filter - CH1
Input Value 1 for Input Correction -
CH1
Input Shift 1 - CH1
Input Value 2 for Input Correction -
CH1
Input Shift 2 - CH1
MV at PV Error - CH1
Standard Control:
Heating and Cooling Control:
MV at Stop - CH1
Standard Control:
Heating and Cooling Control:
MV Upper Limit - CH1
Standard Control:
Heating and Cooling Control:
MV Lower Limit - CH1
Standard Control:
Heating and Cooling Control:
Hysteresis (Heating) - CH1
Hysteresis (Cooling) - CH1
Alpha - CH1
Manual MV - CH1
Standard Control:
Heating and Cooling Control:
SP Upper Limit - CH1
SP Lower Limit - CH1
Disturbance Gain - CH1
Disturbance Time Constant - CH1
Disturbance Rectification Band - CH1
Disturbance Judgment Width - CH1
Input Digital Filter - CH2
Input Digital Filter - CH3
Input Digital Filter - CH4
Parameter name
Heater Burnout 1 Detection
HS Alarm 1
Heater Overcurrent 1 Detection
Heater Burnout 2 Detection
Setting (monitor) range
H' 00000000 to H' 0000270F (0.0 to 999.9)
H' FFFFF831 to H' 0000270F ( 1999 to 9999) (See note 1.)
H' FFFFF831 to H' 0000270F ( 199.9 to 999.9) (See note 2.) 0.0
H' FFFFF831 to H' 0000270F ( 1999 to 9999) (See note 1.)
H' FFFFF831 to H' 0000270F ( 199.9 to 999.9) (See note 2.) 0.0
H' FFFFFFCE to H' 0000041A ( 5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A ( 105.0 to 105.0)
H' FFFFFFCE to H' 0000041A ( 5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A ( 105.0 to 105.0)
H' FFFFFFCE to H' 0000041A ( 5.0 to 105.0)
H' 00000000 to H' 0000041A ( 0.0 to 105.0)
H' FFFFFFCE to H' 0000041A ( 5.0 to 105.0)
H' FFFFFBE6 to H' 00000000 ( 105.0 to 0.0)
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note 2.)
H' 00000001 to H' 0000270F (0.1 to 999.9) (See note 2.)
H' 00000000 to H' 00000064 (0.00 to 1.00)
H' FFFFFFCE to H' 0000041A ( 5.0 to 105.0)
H' FFFFFBE6 to H' 0000041A ( 105.0 to 105.0)
H' FFFFF831 to H' 0000270F ( 1999 to 9999) (See note 1.)
H' FFFFF831 to H' 0000270F ( 1999 to 9999) (See note 1.)
H' FFFFFF9C to H' 00000064 ( 1.00 to 1.00)
H' 00000001 to H' 0000270F (0.01 to 99.99)
H' 00000000 to H' 0000270F (0.0 to 999.9) (See note 2.)
H' FFFFF831 to H' 0000270F ( 199.9 to 999.9) (See note 2.) 0.0
The rest are the same as channel 1.
Setting (monitor) range
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
H' 00000000 to H' 000003E8 (0.0 to 100.0)
The rest are the same as from Heater Burnout Detection 1 to Heater Overcurrent Detection 1.
Appendix
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
HFU
TC2
0.0
s
ch
---
0
EU
ch
---
EU
ch
---
1000
EU
ch
---
EU
ch
---
0
%
ch
---
0
%
ch
---
105.0
%
ch
---
105.0 %
ch
---
1.0
EU
ch
---
1.0
EU
ch
---
0.65
---
ch
---
0
%
ch
---
9999
EU
ch
---
1999
EU
ch
---
0.65
---
ch
---
1.00
---
ch
---
0.0
EU
ch
---
EU
ch
---
TC4
---
TC4
---
De-
Unit
Attrib-
Target Unit
fault
utes
TC4/
HFU
TC2
0.0
A
IO
TC2
---
100.0
A
IO
TC2
---
100.0
A
IO
TC2
---
241