Detecting Current Errors
Normal Operation
5.8 A
200 V
200 V
5.8 A
200 V
To CT input
5.8 A
When each phase's current is normal, the current is: 5.8 A
Heater Burnout Occurred
Burnout
200 V
200 V
5 A
200 V
To CT input
5 A
To CT input
Current when there is a burnout
b. Star Connection
Example: Using Three 200-VAC, 2-kW Heaters
CT
CT
To CT input
Load: Heater
(example)
200 V
CT
CT
1
------ -
= 10 A
3
= 5 A
With this configuration, the heater burnout detection current is as follows:
Heater burnout detection current =
Load: Heater (example)
1
10 A
------ -
3
5 A
Load: Heater
200 V
(example)
5 A
200 V
To CT input
To CT input
3
Current when there is a burnout
------ -
2
5.8
----------------- -
Section 4-5
.
CT
Burnout
CT
= 10 A
= 5 A
+
5
= 5.4 [A]
2
1
3
------ -
------ -
3
2
97