3. Instructions
Basic Timer Specifications
TIM/TIMX
Item
(550)
Decrementin
Timing method
g
Timing units
100 ms
TIM: 999.9 s
TIMX:
Maximum SV
6,553.5 s
Outputs/
1
instruction
Timer numbers
Used
When the
Completion
instruction is
Flag refreshing
executed
TIM PVs are
refreshed
when the
instruction is
executed,
after
Timer PV
executing all
refreshing
cyclic tasks
(See note)
each cycle,
or every
80 ms by
interrupt if
the cycle
time exceeds
80 ms.
Com-
OFF
ple-
Value
tion
after
Flags
reset
PVs
SV
Note Timers are refreshed at different times depending on the timer number. Refer to the descriptions of individual timer
instructions for details
TIM/TIMX
Item
(550)
Operating mode
PV = 0
change
Completion Flag = OFF
PV = 0
Power interrupt/reset
Completion Flag = OFF
Execution of
Binary: PV = FFFF, Completion Flag = OFF
CNR(545)/CNRX(547)
BCD: PV = FFFF or 9999, Completion Flag = OFF
Operation in jumped
Operating timers continue timing.
program section
(JMP(004)-JME(005))
Operation in inter-
PV = SV
locked program sec-
Completion Flag = OFF
tion (IL(002)-ILC(003))
Comple-
ON
Forced
tion Flag
set
PVs
Set to 0.
Comple-
OFF
Forced
tion Flags
reset
PVs
Reset to SV.
Note It is not possible to read the timer PVs of TIMU(541), TIMUX(556), TMUH(544), and TMUHX(557).
206
TIMH(015)/
TMHH(540)/
TIMU(541)/
TIMHX(551)
TMHHX(552)
TIMUX(556)
(See note 3.)
Decrementing
Decrementing
Decrementing
10 ms
1 ms
0.1 ms
TIMH: 99.99 s
TMHH: 9.999 s
TIMU:
TIMHX:
TMHHX:
0.9999 s
655.35 s
65.535 s
TIMUX:
6.5535 s
1
1
1
Used
Used
Used
When the
When the
When the
instruction is
instruction is
instruction is
executed
executed
executed
TIMH(015)/TI
• Every 1 ms
• The PV
MHX(551) PVs
• When the
are refreshed
instruction is
when the
executed
instruction is
executed, after
executing all
cyclic tasks
each cycle,
and every 10
ms by
interrupt.
OFF
OFF
OFF
SV
SV
---
TIMH(015)/
TMHH(540)/
TIMHX(551)
TMHHX(552)
TMUH(544)/
TTIM(087)/
TMUHX(557)
TTIMX(555)
(See note 3.)
Decrementing
Incrementing
0.01 ms
100 ms
TMUH:
TTIM: 999.9 s
0.09999 s
TTIMX:
TMUHX:
6,553.5 s
0.65535 s
1
1
Used
Used
When the
When the
instruction is
instruction is
executed
executed
• The PV
When the
cannot be
cannot be
instruction is
read.
read.
executed
OFF
OFF
0
TIMU(541)/
TMUH(544)/
TIMUX(556)
TMUHX(557)
--- (See note.)
--- (See note.)
CS/CJ/NSJ Series Instructions Reference Manual (W474)
TIML(542)/
MTIM(543)/
TIMLX(553)
MTIMX(554)
Decrementing
Incrementing
100 ms
100 ms
TIML:
MTIM: 999.9 s
115 days
MTIMX:
TIMLX:
6,553.5 s
49,710 days
1
8
Not used
Not used
When the
When the
instruction is
instruction is
executed
executed
When the
When the
instruction is
instruction is
executed
executed
OFF
OFF
SV
0
TTIM(087)/
TIML(542)/
MTIM(543)/
TTIMX(555)
TIMLX(553)
MTIMX(554)
---
---
---
---
Not
Not
applicable
applicable
Timer status is maintained.
Timer status
PV = SV
Timer status
maintained.
Completion
maintained.
Flag = OFF
---
---
Set to 0.
---
---
---
---
Set to 0.
---
---