4.2
Models available
Designation
DB 12 LSM C13 A0 FB TC FS1 T15
4.3
Burner categories - Countries of destination
Country of destination
SE - FI - AT - GR - DK - ES - GB - IT - IE - PT - IS - CH - NO
4.4
Technical data
Model
Output
(1)
Fuels
Gas pressure at max. output
Gas: G20/G25
Operation
Modulation/maximum output ratio
Nozzles
Combustion air temperature
Ignition
Weight
Reference conditions: Ambient temperature 20°C - Gas temperature 15°C - Barometric pressure 1013 mbar - Altitude 0 m a.s.l.
(1)
Pressure at the socket (Fig. 8) with zero pressure in the combustion chamber and at maximum burner output.
(2)
4.5
Electrical data
Model
Electrical supply
Ignition transformer
Absorbed electrical power
Protection level
20119307
Technical description of the burner
DE
NL
FR
BE
LU - PL
kW
min - max
kg/h
-
(2)
mbar
No.
°C max
kg
V1 - V2
I1 - I2
Gas
kW max
Gas oil
kW max
Voltage
230 V / 50-60 Hz
–
Natural gas: G20 - NCV 10 kWh/Nm
–
Natural gas: G25 - NCV 8.6 kWh/Nm
–
Light oil, max. viscosity at 20 °C: 6 mm
–
FS1 Intermittent (min. 1 stop every 24 hours)
–
Modulating
Electrogas type (pilot burner with natural gas)
8
GB
Code
20119009
Gas category
I
2H
I
2ELL
I
2L
I
2Er
I
2E(R)B
I
2E
DB 12 LSM C13
1700/7000 ÷ 12500
144/593 ÷ 1059
3
3
2
/s (1.5°E - 6 cSt)
97.2/145
Natural gas 1 : 5
Light oil 1 : 4
1
150
350
DB 12 LSM C13
230V - 50/60Hz
230 V - 1 x 8 kV
1.4 A - 30 mA
0.5
0.6
IP 54
Tab. A
Tab. B
Tab. C
Tab. D