TROUBLESHOOTING
E1 Auger Jam
Clearing an Auger Jam
To clear the E1 error code from the controller, please follow these steps:
1. When the grill has completed the shutdown procedure and
completely cooled, power off the grill and unplug from power source.
2. From the rear of your SMOKEFIRE grill, place a large bucket or
container underneath the middle of the hopper (A).
3. Pull the hopper slide door located on the rear of the hopper to
release the pellets into the container below (B).
4. From the rear of your SMOKEFIRE grill, remove the rear access panel
by removing four screws (C).
5. Disconnect wire connection from the motor by pinching the clip and
pulling the quick disconnect plug. (D).
6. Remove the auger/motor assembly by first removing three screws
and washers from the mounting bracket (E). Carefully slide and twist
the auger/motor assembly out and away from the grill (F).
NOTE: Visually note the orientation of the motor when installed on the grill.
A
B
24
C
D
E
F