Tektronix Phaser 560 User Manual page 183

Color laser printer
Hide thumbs Also See for Phaser 560:
Table of Contents

Advertisement

Troubleshooting and print quality quick reference (cont'd.)
Symptom
On the Consumables Page,
each color "bleeds" into the
color band below it (the most
visible is magenta in the
yellow band).
A single white spot appears
in approximately the same
vertical place on the page.
A single, wide, light horizontal
band appears in one place on
the page (near the top) or all
colors are faded.
Possible Causes
The Imaging Unit's internal waste
toner box is full.
The Imaging Unit is damaged.
The Imaging Unit was exposed too
long to light.
Troubleshooting
Solution
Replace the Imaging Unit.
Replace the Imaging Unit.
Wait overnight and print the Consumables
Page. If print quality hasn't changed,
replace the Imaging Unit.