GENERAL REMARKS
The following table lists the programmable parameters; if the adjustment board does not support the relative func-
tion, the interface returns an error message.

1.13 Structure menu

For a detailed explanation of the parameters, refer to paragraph "1.14 Description of the parameters".
Parame-
Scrolling message
Menu
ters
only if parameter P1.05 = 1
P1
SETTINGS
P1.01
LANGUAGES
P1.02
TIME
P1.03
TIME PROGRAM
P1.05
SCROLLING
P1.07
SEASON AUTO-CHANGE
P1.08
T TRANSITION TO SUM
P1.09
T TRANSITION TO WIN
P3
CONFIGURATION
P3.01
HYDRAULIC CONFIGURATION
P3.02
WATER PRESSURE TRANSDUCER
P3.03
AUTO FILL ENABLE
P3.04
BEGIN SYSTEM FILLING
P3.05
AIR PURGING CYCLE
P3.06
MIN FAN SPEED
P3.07
MAX FAN SPEED
P3.08
SLOW IGNITION ADJUSTMENT
P3.09
MAX FAN SPEED HTG
P3.10
RANGE RATED
P3.11
CONFIG AUX
P3.12
EXHAUST PROBE RESET
IGNITION SPEED IN RESTART AFTER
P3.13
SHUTDOWN DUE TO TEMPERATURE
P4
HEATING
P4.01
HYST OFF HIGH TEMP
P4.02
HYST ON HIGH TEMP
P4.03
HYST OFF LOW TEMP
P4.04
HYST ON LOW TEMP
P4.05
PUMP CONTROL TYPE
P4.08
OT+ CASCADE CONTROL
P4.09
SCREED FUNCTION
P4.10
ANTI CYCLE FUNCTION
P4.11
RESET CH TIMERS
P4.12
MAIN ZONE ACTUATION TYPE
P4.13
MAIN ZONE BE16 ADDRESS
P4.14
MAIN ZONE HYDRAULIC CONF
P4.15
MAIN ZONE LOW TEMP
P4.16
MAX CH SET
P4.17
MIN CH SET
P4.18
WEATHER COMP ENABLE
P4.19
WEATHER COMP CURVE
P4.20
NIGHT COMPENSATION
P4.21
POR MAIN ZONE
HT = HIGH TEMPERATURE ● LT = LOW TEMPERATURE
(°)
0 = HEATING ONLY - 1 = INSTANTANEOUS BOILER WITH FLOW SWITCH - 2 = INSTANTANEOUS BOILER WITH FLOW METER -
3 = STORAGE TANK WITH PROBE - 4 = STORAGE TANK WITH THERMOSTAT
Value
6 ES
0 IT
7 EL
1 RO
8 BG
2 FR
9 PL
3 EN
10 SL
4 SR
5 HR
NOT AVAILABLE
0 / 1
0 / 1
P1.09/40°C
0°C / P1.08
P1.08 and P1.09 visible only if P1.07 =1
0 / 1 / 2 / 3 / 4
0 / 1
0 / 1
NOT AVAILABLE ON THIS MODEL
0 / 1
1.200-3.600
3.700-9.999
MIN-MAX
MIN - MAX
NOT AVAILABLE ON THIS MODEL
0 / 1 / 2
0 / 1
MIN FAN SPEED/ SLOW IGNITION
ADJUSTMENT
2 - 10
2 - 10
2 - 10
2 - 10
60 - 100
NOT AVAILABLE ON THIS MODEL
0 / 1
0 - 20 min
0 / 1
0 / 1
1 - 6
0 / 1
0 / 1
HT: MIN CH SET - 80
LT: MIN CH SET - 45,0
HT: 20 - MAX CH SET
LT: 20 - MAX CH SET
0 (default)/1
1,0-3,0
HT
0,2-0,8
LT
0 / 1
DO NOT MODIFY
14
Password
Value set
level
in the factory
USER
USER
0
USER
0
USER
20°C
USER
15°C
USER
INSTALLER
0 (°)
SERVICE
1
SERVICE
0
SERVICE
1
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
see technical data
INSTALLER
table
INSTALLER
0
INSTALLER
0
min value between
INSTALLER
3.600 rpm and P308
SERVICE
5
SERVICE
5
SERVICE
3
SERVICE
3
INSTALLER
85
INSTALLER
0 (boiler in OFF and P4.15=1)
INSTALLER
3 min
INSTALLER
0
INSTALLER
0
INSTALLER
3
INSTALLER
0
INSTALLER
0
80
INSTALLER
45,0
40
INSTALLER
20
INSTALLER
0
INSTALLER
2,0
INSTALLER
0
0