Riello CONDEXA HPR Series Instructions For The Installer And For The Technical Assistance Centre page 15

Table of Contents

Advertisement

Parame-
Scrolling message
Menu
ters
only if parameter P1.05 = 1
P4.22
MAN AUTO MAIN ZONE
P4.23
ZONE1 ENABLE
P4.24
ZONE1 BE16 ADDRESS
P4.25
ZONE1 HYDRAULIC CONFIG
P4.26
ZONE1 LOW TEMP
P4.27
ZONE1 SET
P4.28
ZONE1 MAX CH SET
P4.29
ZONE1 MIN CH SET
P4.30
WEATHER COMP ZONE 1
P4.31
WEATHER COMP CURVE ZONE 1
P4.32
ZONE1 NIGHT COMP
P4.33
BUILDING TYPE
P4.34
EXTERNAL PROBE REACTIVITY
P5
DHW (°°)
P5.01
ANTI LEGIONELLA
P5.02
DELAY FIRST ANTI LEGIONELLA
P5.03
DELIVERY TEMP FOR ANTILEG
P5.04
HYST WATER TANK ON
P5.05
HYST WATER TANK OFF
P5.06
DELIVERY WATER TANK TEMP
P5.07
SLIDING WATER TANK DELIVERY
P5.08
MIN DHW TEMP
P5.09
MAX DHW TEMP
P5.12
DHW POST-CIRC. ON HEAT. RETURN 0 / 1
P5.13
RETURN POST-CIRC TIME
P5.14 (SIMULTANEOUS DHW AND
P5.14
HEATING)
P5.15
P5.15 (OFFSET DHW SETPOINT)
P6
SOLAR
P6.01
ENABLE SOLAR TANK MANAGEMENT
P6.02
MAX TANK TEMPERATURE
P6.03
PUMP ON DELTA T
P6.04
PUMP OFF DELTA T
P6.05
INTEGRATION DELAY
P6.06
COLLECTOR T MIN
P6.07
COLLECTOR T MAX
P6.08
COLLECTOR T PROT
P6.09
COLLECTOR T AUTH
P6.10
COLLECTOR T LOCK
P6.11
PWM COLL PUMP
P6.12
TANK COOLING
P6.13
SOLAR PUMP MODE
P7
SERVICE
P7.06
SERVICE CALL FUNCTION
P7.07
SERVICE DEADLINE
P7.08
HIGH EFFICIENCY MODE
P8
CONNECTIVITY
P8.01
BUS 485 CONFIG.
P8.03
OT+ CONFIG.
P9
CASCADE
P9.01
CASCADE CONFIGURATION
ADDITIONAL BOILER FLOW RAN-
P9.02
GE
(°°) Menu P5 DHW is only visible when parameter P3.01 Hydraulic configuration = 3 or 4 - case C or B
Value
DO NOT MODIFY
0 / 1
1 - 6
0 / 1
0 / 1
ZONE1 MIN CH SET -
ZONE1 MAX CH SET
HT: ZONE1 MIN CH SET - 80,5
LT: ZONE1 MIN CH SET - 45,0
HT: 40 - ZONE1 MAX CH SET
LT: 20 - ZONE1 MAX CH SET
0 / 1
1,0-3,0
HT
0,2-0,8
LT
0 / 1
5min ÷ 20min
0÷255
0/2
0 h/24h
65,0 °C/ 85,0 °C
0,0 °C/ 10,0 °C
0,0 °C/ 10,0 °C
50,0 °C/ 85,0 °C
0 / 1
37,5 °C/ 49,0 °C
49,0 °C/ 60,0 °C
1/ 255
0 / 1
0°C / 10°C
0 / 1
10 ÷ 130
PUMP OFF DELTA T 30°C
4°C PUMP ON DELTA T
0min - 199min
(--)/-30°C - 0
COLLECTOR T PROT - 180°C
80°C - COLLECTOR T MAX
COLLECTOR T LOCK - 95°C
-20°C - COLLECTOR T AUTH
0min - 30min
0 / 1
0 / 1 / 2
0 / 2
0 / 255
0 / 1
0 / 1 / 2
0 / 1
0/1/2/3/4
30/95
15
GENERAL REMARKS
Password
Value set
level
in the factory
0
INSTALLER
0
INSTALLER
1
INSTALLER
0
INSTALLER
0
40 - 80,5
USER
INSTALLER
80,5
INSTALLER
40
INSTALLER
0
INSTALLER
2,0
INSTALLER
0
INSTALLER
5min
INSTALLER
20
INSTALLER
0
INSTALLER
0 h
INSTALLER
80,0 °C
INSTALLER
5,0 °C (ext) - 0,0 °C (int)
INSTALLER
5,0 °C (ext) - 0,0 °C (int)
80,0 °C (if external
INSTALLER
water tank and par.
507=0)
INSTALLER
0
INSTALLER
37,5°C
INSTALLER
60,0°C
SERVICE
0
SERVICE
6
SERVICE
0
SERVICE
0°C
INSTALLER
0
INSTALLER
60°C
INSTALLER
8°C
INSTALLER
4°C
INSTALLER
0 min
INSTALLER
(--)
INSTALLER
110°C
INSTALLER
110°C
INSTALLER
40°C
INSTALLER
35°C
INSTALLER
0 min
INSTALLER
0
INSTALLER
0
SERVICE
2
SERVICE
52
SERVICE
0
SERVICE
0
SERVICE
1
SERVICE
0
SERVICE
80
Personali-
sed
values