Control Panel - Riello CONDEXA HPR Series Instructions For The Installer And For The Technical Assistance Centre

Table of Contents

Advertisement

1.12 Control panel

+
A
B
1
Normally
used
A
temperature value, but when the arrow
highlighted it acts as a confirmation button
Normally
used
B
temperature value, but when the arrow
highlighted it acts as a back/annul button
Normally used to increase the heating water
C
temperature value, but when the arrow
highlighted it allows you to navigate menu P1
Normally used to decrease the heating water
D
temperature value, but when the arrow
highlighted it allows you to navigate menu P1
Access to the clock setting menu (see paragraph
A+C
"3.2 Programming the boiler")
Used to modify the boiler operating status
1
(OFF, SUMMER and WINTER)
Used to reset the alarm status, or to interrupt
2
the venting cycle
Used to access the INFO menus and menu P1.
Enter
When the
3
this button has an ENTER function and is used
to confirm the value set while programming a
technical parameter
1+3
Button lock and release
Used when the boiler is OFF, to activate the
2+3
flue gas analysis function (CO)
9
The DHW function is only shown on the display in cases B and C (see paragraph "1.3 Boiler description").
The control panel acts as a machine interface, displaying the system settings and providing access to the parame-
ters.
The configuration MENU is organised with a multi-level tree structure. An access level has been fixed for each sub-
menu: USER level always available; TECHNICAL level protected by means of a password.
Below is a summary of the SETTINGS MENU tree structure.
Some of the information might not be available depending on the access level, machine
status, system configuration or software revision.
+
RESET
MENU
2
3
to
increase
the
to
decrease
the
icon appears on the display,
Indicates the connection to a remote device
(OT or RS485)
C
lndicates the connection to a wi-fi device
Indicates the presence of an outdoor tem-
perature sensor
D
Indicates the activation of special DHW
functions, or the presence of a solar thermal
management system
Lights up if an alarm is triggered
Lights up along with the icon
event of a fault (apart from flame and wa-
ter alarms)
Indicates the presence of a flame (
DHW
the event of a flame lockout)
is
Lights up for alarms requiring a manual reset
Reset
by the operator
DHW
is
Enter
Lights up when confirmation is required
When this icon is active, the "confirm"
function of button A is active
is
When this icon is active, the "back/annul"
function of button B is active
When this icon is active, the user can
is
navigate the menu or increase the value of
the selected parameter
When this icon is active, the user can
navigate the menu or decrease the value of
the selected parameter
Lights up if heating mode is active; flashes
with a heating request in progress
Lights up if DHW mode is active; flashes
with a DHW request in progress
Indicate
notch=minimum value, 4 notches=maximum
value)
Indicate the days of the week
1 2 3 4 5 6 7
ON NOT AVAILABLE ON THIS MODEL
AUTO
MAN ON
NOT AVAILABLE ON THIS MODEL
MAN OFF
NOT AVAILABLE ON THIS MODEL
13
GENERAL REMARKS
the
setpoint
defined
in the
in
(1

Advertisement

Table of Contents
loading

This manual is also suitable for:

Condexa hpr 35Condexa hpr 452019940020199401