Temperature of the flue gases in nominal conditions (at 80/60°C) [°C]
Mass flow rate [m
/h] @ nominal output [kW]
3
Nominal output
[kW]
Overtemperature of the flue gases [°C]
Temperature of the flue gases at minimum output [°C]
Mass flow rate at the minimum heat output [m
Minimum nominal output
[kW]
CO
content in nominal conditions [%]
2
CO
at the minimum heat output [%]
2
Loss of minimum permitted pressure (in air feed and flue gas pipe) [Pa]
Loss of maximum permitted pressure (in air supply and flue gas pipe) [Pa]
Maximum permitted pressure difference between combustion air inlet and
flue gas outlet (including wind pressure) [Pa]
Maximum permitted combustion air temperature [°C]
Minimum effective diameter of the flue/utility compartment [mm]
Notes
C1:
For the installation of the terminals on the wall and roof, refer to the specific instructions contained in the kits.
The terminals emerge from separate combustion and air supply circuits within a square area of 50 cm.
C3:
The terminals of the separate combustion and air supply circuits must lie within a square area of 50 cm, and the distance between the surfaces
of the two holes must be less than 50 cm.
C4:
The boilers in this configuration, with the relative connection pipes, can be connected to only one natural draught stack.
Condensate flow inside the appliance is not permitted.
C5:
The terminals for combustion air supply and the evacuation of flue gases must not be installed on opposite walls of the building.
C6:
Condensate flow inside the appliance is permitted.
Maximum permitted recirculation rate of 10% in windy conditions.
The terminals for combustion air supply and the evacuation of flue gases must not be installed on opposite walls of the building.
This type of configuration is not permitted in some countries; refer to the local regulations in force.
C8:
Condensate flow inside the appliance is not permitted.
Description
/h] @ reduced power [kW]
3
C9
35
45
C4
58
59,8
3,77
4,864
35,4
45,47
43,3
43,3
0,886
0,886
8,3
8,3
8,94
9,08
5,40
5,40
15
23
160
192
-
-
-
-
35
9
GENERAL REMARKS
Condexa HPR boiler type
35
45
35
C6
C8
72,2
75,5
55,3
3,816
4,849
3,929
35,78
45,44
36,86
115
59,4
59,4
42,9
0,606
0,606
1,292
5,66
5,66
12,09
10,31
10,39
7,18
10,01
10,01
4,00
-
-
-
-
-
-
15
23
-
45
45
-
45
240
45
56,7
4,976
46,56
42,9
1,34
12,54
8,15
4,00
-
-
-
-

Advertisement