11 PART REPLACEMENT METHOD

11.1.1 Nozzle clearance home position adjustment

While pressing the
1.
After carrying out steps 2 to 7 in "4.1 Starting the machine", touch ▼ which is displayed on the screen.
2.
3.
Touch "Clearance adjustment".
4.
The following screen will be displayed, so touch "Clearance",
Adjust the nozzle position while referring to "11.1.2 Adjusting the nozzle position (feed direction)"
5.
Insert a 0.5 mm thickness gauge in between the nozzle and the nozzle lower roller as shown in the image below, and
then touch
or
nozzle and the nozzle lower roller is the same as the thickness gauge, touch
80
key, turn on the power switch.
to adjust the position of the nozzle lower roller. Once the amount of clearance between the
BM-2000
.
Nozzle
0.5 mm thickness gauge
Roller under nozzle