12 STANDARD ADJUSTMENTS
Raise the nozzle lever (9) and the upper edge control roller (10).
5.
Push the flat bed (11) from the back until it covers the mounting stay (8), and then secure it by tightening the two M4
screws with washer (12).
At this time, be careful that the flat bed (11) is not lifted up from the mounting stay (8).
*
To remove the flat bed, follow the installation procedure in reverse.
108
(9)
(10)
(11)
(8)
(12)
BM-2000