Adjustment
Needle clearance left/right adjustment
1. Turn the pulley by hand until the tip of the needle enters the needle hole.
2. Loosen the screw (3X10).
3. Move the needle holder shaft block to the left or right so that the needle drop is centered over the needle hole on
needle plate A at the left base line and right base line.
4. Tighten the screw (3X10).
4 - 7