5 Correct use

Danger of explosion!
▶ Risk of severe injury or death
Only versions that have been approved
according to their technical data may
be used in potentially explosive envir-
onments.
Improper use of the product!
▶ Risk of severe injury or death
▶ Manufacturer liability and guarantee will be void
Only use the product in accordance with the operating
conditions specified in the contract documentation and in
this document.
The GEMÜ 4242 with integrated pilot valve is designed for
pneumatic actuators. The product has a microprocessor-con-
trolled intelligent position sensor as well as an analogue
travel sensor system (potentiometer). It is non-positively con-
nected with the actuator spindle by means of a mounting kit
(spring, operating bush). The valve end positions and the in-
tegrated travel sensor can be controlled via the electrical con-
nections. The pneumatic valve actuator is directly activated
by an integrated 3/2-way pilot valve. The housing cover must
not be removed.
5.1 Product without special function X
The product is not intended for use in potentially explosive
areas.
5.2 Product with special function X
The product with ordering option Special version X is intended
for use in potentially explosive areas of zone 2 with gases,
mists or vapours and zone 22 with combustible dusts in ac-
cordance with EU directive 2014/34/EU (ATEX) and IECEx.
The product has the following explosion protection marking:
ATEX
Gas:
II 3G Ex ec nC IIC T4 Gc X
Dust:
II 3D Ex tc IIIC T100°C Dc X
The product has been developed in compliance with the fol-
lowing harmonised standards:
- EN IEC 60079-0:2018
- EN IEC 60079-7:2015/A1:2018
- EN 60079-31:2014
Use of the product is permissible in the following ambient
temperature ranges: 0 to +60 °C
For use in potentially explosive areas, the following
conditions or operation limits must be observed:
Index X is applied to the explosion protection marking.
www.gemu-group.com
DANGER
WARNING
The following special conditions must be complied with:
1. Connection cables and connectors must be protected
from damage.
2. Layers of dust > 5 mm must be removed.
3. Warning label "Danger from electrostatic build-up".
4. Warning label "Do not disconnect when live".
The housing must be installed protected from mechanical in-
fluences.
RFID chips must not be read out in potentially explosive areas.
7 / 51