14 App parameter list
No.
Parameter
P03
Switch point OPEN
P04
Switch point CLOSED
Total operating hours
Localization
S06
Control function
S07
Firmware version
P05
High visibility position indic-
ator
P06
Inversion of LED colours
Operating hours since last
start
S03
Total switching cycle counter
S02
Warning threshold for user
switching cycles
S01
User switching cycle counter
P01
Detection of end positions
mode
P02
Initialization via magnet con-
tact
S09
Operating time OPEN
S10
Operating time CLOSED
S11
Product start counter
Current absolute position
Bluetooth product name
S12
Production ID
M01
Operating mode
Manual valve control
Valve actuations warning ra-
tio
S08
Hardware version
P09
Inversion of the travel sensor
signal
P07
Error position
P14
Digital input 1 function
www.gemu-group.com
Description
Defines switch point OPEN
Defines switch point CLOSED
Displays the total operating
hours
Activates/deactivates the loc-
ation function
Displays the determined con-
trol function of the valve
Displays the firmware revision
status
Activates/deactivates the
visual end position display
Activates/deactivates the in-
version of LED colours for the
end position display
Displays operating hours since
the last start
Displays the total number of
counted switching cycles
Defines the warning threshold
for user switching cycles
Displays the number of coun-
ted user switching cycles
Defines the end position de-
tection mode
Activates/deactivates initializ-
ation via magnet contact
Displays the duration of open-
ing the valve
Displays the duration of clos-
ing the valve
Displays the number of
product starts
Displays the absolute position
of the travel sensor
Defines the name in the
product overview
Displays the production ID
Defines the operating mode
Defines the valve activation
Displays the relative degree of
wear on the pilot valve module
Displays the hardware version
Activates/deactivates inver-
sion of the travel sensor signal
Defines the valve position in
the event of error detection
Defines the function of digital
input 1
25 / 51
Value range
3 ... 97 %
3 ... 97 %
0 ... 2147483647 s
Deactivated
Activated
Undefined
NC
NO
DA
0 ... 21
Dimmed
Deactivated
Activated
Deactivated
Activated
0 ... 2147483647 s
0 ... 2147483647
0 ... 2147483647
0 ... 2147483647
Classic
Autonomous
Deactivated
Activated
0 ... 99,9 s
0 ... 99,9 s
0 ... 2147483647
0 ... 1
0 ... 16
Auto
Manual
0 ... 100 %
Deactivated
Activated
Hold position
Open
Closed
Safety position
Deactivated
Activation of pilot valve 1
Initialization input
Localization
Safety position
14 App parameter list
Default setting
75
12
0
Deactivated
Undefined
V0.0.0.0
Activated
Deactivated
0
0
5000000
0
Autonomous
Activated
Auto
0
Deactivated
Safety position
Activation of pilot valve 1