GEM 4242 Operating Instructions Manual page 39

Combi switchbox with integrated pilot valve
Table of Contents

Advertisement

15.3 Non-cyclical condition monitoring data
Port
Index
"Access
[Hex]
Rights"
1
0x656
RO
1
1
0x656
RO
2
1
0x656
RW
3
1
0x656
RO
4
1
0x656
RO
5
1
0x656
RW
6
1
0x656
RO
7
1
0x65A
RO
1
1
0x65A
RO
2
1
0x662
RO
1
1
0x662
RO
2
www.gemu-group.com
Parameter
"Lengt
h"
User switching
32 bit
cycle counter
Total switching
32 bit
cycle counter
Warning threshold
32 bit
for user switching
cycles
Valve actuations
32 bit
user counter
Valve actuations
32 bit
total counter
Warning threshold
32 bit
for valve actu-
ations user counter
Switching cycles
16 bit
warning ratio
Total operating
32 bit
hours
Operating hours
32 bit
since last start
Operating time
16 bit
OPEN
Operating time
16 bit
CLOSED
"Data
"De-
type"
fault
set-
ting"
uint:32 0 *
uint:32 0 *
uint:32 0 *
uint:32 0 *
uint:32 0 *
uint:32 0 *
uint:16 0 *
uint:32 0 *
uint:32 0 *
uint:16 -
uint:16 -
39 / 51
15 Specific data – AS-Interface
"Adjustment facil-
"Description"
ity"
0 ... 2.147.483.647
(OPEN -> CLOSED
-> OPEN = switch-
ing cycle feedback)
can be reset (for ex-
ample, after repla-
cing the diaphragm)
0 ... 2.147.483.647
(OPEN -> CLOSED
-> OPEN = switch-
ing cycle feedback)
cannot be reset (ac-
tuator switching
cycles)
1 ... 2.147.483.647
Adjustable alarm
threshold for user
switching cycles
(cycle counter user)
0 ... 2.147.483.647
Counts the actu-
ation pulses (even
if they do not result
in movement of the
actuator). Can be
reset (for example,
after replacing the
pilot valve module)
0 ... 2.147.483.647
Counts the actu-
ation pulses (even
if they do not result
in movement of the
actuator).
1 ... 2.147.483.647
Adjustable alarm
threshold for actu-
ation pulse counter
0 to 1000 (0 to
Pilot valve wear
100.0%)
level in %. Calcu-
lated from the actu-
ation counter and
the set alarm
threshold
0 ... 2.147.483.647
Total operating
hours counter
0 ... 2.147.483.647
Operating hours
since last device
start
0 to 999 (0.0 to
Travel time from
99.9 s)
OPEN to CLOSED
end position
0 to 999 (0.0 to
Travel time from
99.9 s)
CLOSED to OPEN
end position
GEMÜ 4242

Advertisement

Table of Contents
loading

Table of Contents