5 Correct use
5 Correct use
Danger of explosion!
▶ Risk of severe injury or death.
Do not use the product in potentially explosive zones.
●
Only use the product in potentially explosive zones confirmed in the declaration of conformity.
●
Improper use of the product
▶ Risk of severe injury or death.
▶ Manufacturer liability and guarantee will be void.
Only use the product in accordance with the operating conditions specified in the contract documentation and in this doc-
●
ument.
The product with the special version X order option is intended for use in potentially explosive areas of zone 2 with gases,
mists or vapours and zone 22 with combustible dusts in accordance with EU directive 2014/34/EU (ATEX).
The product has the following explosion protection marking:
ATEX
Gas:
II 2G Ex ib IIB T4 Gb
Dust:
II 2D Ex ib IIIC T120°C Db
EC type examination certificate: IBExU17ATEX 1160 X
Notified body: IBExU, No. 0637
IECEx
Gas:
Ex ib IIB T4 Gb
Dust:
Ex IIIC T120°C Db
Certificate: IECEx IBE 19.0017 X
The product has been developed in compliance with the following harmonised standards:
–
EN 60079-0:2012+A11:2013
–
EN 60079-11:2012
The product can be used in the following ambient temperature ranges: 0 °C to +50 °C
For use in potentially explosive areas, the following conditions or operation limits must be observed:
Special conditions of use
1. The special conditions of the Ex components used must be observed.
2. The housing must be installed protected against mechanical influences.
3. Layers of dust > 5 mm must be avoided.