GEM 4242 Operating Instructions Manual page 34

Combi switchbox with integrated pilot valve
Table of Contents

Advertisement

15 Specific data – AS-Interface
Port
Index
"Access
[Hex]
Rights"
1
0x64F3 RW
1
0x6501 RW
1
0x6503 RW
1
0x6504 RW
1
0x6505 RW
1
0x6506 RW
1
0x6509 RW
1
0x6511 RW
1
0x6512 RW
1
0x6531 RO
GEMÜ 4242
Parameter
"Length
Time-based diagnostic
8 bit
messages
Inversion of LED col-
1 byte
ours
Detection of end posi-
1 byte
tions mode
Initialization via mag-
1 byte
netic switch
Fieldbus communica-
8 bit
tion
Bluetooth interface
1 byte
High-visibility position
1 byte
indicator
Switch point OPEN
2 byte
Switch point CLOSED
2 byte
Absolute travel sensor
2 byte
position OPEN end po-
sition
"Data
"Default set-
"
type"
ting"
uint:8
1 (activated) 1
uint:8
Standard or
inversed de-
pending on
the order
version
uint:8
1
(autonom-
ous)
uint:8
1
(activated)*
uint:8
0
(deactiv-
ated)
uint:8
1
(activated) *
uint:8
1
(On)
uint:16 75.0%
uint:16 12.0%
uint:16 0
34 / 51
"Adjustment
"Description"
facility"
3
Vent valve
The valve is vented
(approach
and thereby moved to
safety posi-
the safety position
tion)
1 activated
Diagnostic messages
activated
0 deactiv-
ated
Diagnostic messages
deactivated
0
Standard
CLOSED = green,
OPEN = orange
1
Inversed
CLOSED = orange,
OPEN = green
0
Classic
Classic initialization
mode
1
Autonomous Autonomous end posi-
tions tracking
0
Deactivated Programming proced-
ure starting via reed
contact deactivated
1
Activated
Programming proced-
ure starting via reed
contact possible
0
Deactivated Fieldbus communica-
tion deactivated
1
Activated
Fieldbus communica-
tion activated
0
Deactivated Bluetooth communica-
tion option deactiv-
ated
1
Activated
Bluetooth communica-
tion option activated
0
Off
End position feedback
via LEDs deactivated
1
On
End position feedback
via LEDs activated
2
Dimmed
Dimmed end position
feedback via LEDs
-
10.0 to
Set switching
100.0%
threshold for Open
Must be at least 10.0%
higher than switch
point Closed
-
0.0 to 90.0% Set switching
threshold for Closed
Must be at least 10.0%
lower than switch
point Open
-
0.0 to
Initialized travel
100.0%
sensor position OPEN
end position
www.gemu-group.com