INTRODUCTION

Steam Cooking
Large capacity pressure steamers offer an efficient
way to produce a wide variety of foods in small
portions or larger batches. Steamers can be used to
cook fresh foods, blanch foods for complete cooking
later or will steam defrost and cook frozen foods.
Cooking with steam assures the food will retain its
maximum color, flavor and nutritional value with the
least expenditure of energy and labor.

Compartment Pan Capacity

PANS PER
COMPARTMENT
4
12" x 20"
6
12" x 20"
8
12" x 20"
6
*18" x 20"
* Remove center support for 18x20 inch pans

Model Designations

V L X X XX
Cooking Control Types:
PS - Prevent Steam
AS - Automatic Steam
SS - Standard Steam
MS - Manual Steam
Heating System:
G - Gas
E - Electric
D - Direct
R - Regenerated
Number of Compartments
Large Capacity Pressure
Steamer
Vulcan
VL SERIES STEAMERS - GENERAL

GENERAL

DEPTH
SIZE
(INCHES)
6.0
4.0
2.5
1.0
Boiler Code Descriptions
Vulcan-Hart incorporates redundant controls in
compliance with California Code (Cal-Code) and
CSD-1 as an option on steam equipment when
required by state and/or local building code
requirements. Descriptions of the codes are listed
below.
Cal-Code Construction - Redundant controls in the
electrical safety circuits that, if tripped, must
manually be reset after the condition causing the trip
subsides. These controls consist of one dual
function water level cycling and low level cut off
control and one single function low water level cut-
off control (Aux - LLCO) and a high pressure relief
switch in conjunction with a mechanical pressure
relief valve.
CSD-1 Construction - Redundant controls in the
electrical safety circuits that, if tripped, must
manually be reset after the condition causing the trip
subsides. These controls consist of one dual
function water level cycling and low level cut off
control and one single function low water level cut-
off control (LLCO) and a high pressure relief switch
in conjunction with a mechanical pressure relief
valve. Additionally, both circuits have individual
indicator lights that will illuminate for a visual
verification of the shutdown mode.
Cal-Code and CSD-1 construction both require
operator intervention in the event of a shutdown.
CSD-1 is more informative by using indicator lights
to show which safety system was shutdown.

WATER CONDITIONING

Furnishing the boiler with soft water to reduce scale
formation is important. Scale formation will reduce
steam output, cause premature component failure,
and shorten equipment life. Most water supplies
contain scale producing minerals such as Calcium
and Magnesium. As steam is generated, the
minerals remain and dissolve into the water. As the
concentration of these minerals increases past a
certain point, they precipitate from the water and
coat the inside of the boiler, heating elements,
thermostat bulbs and water level probes. Because of
the high temperature of these surfaces, the
precipitated minerals bake onto them and become
very difficult to remove.