Features


Requires no water or drain line connections
(manual fill & manual drain)

Cast aluminum "element block" for efficient
heat transfer and distribution

Field convertible to single phase or three
phase power

When wired for single phase, a reduced 2/3
power output is available

Steam Cooking

The VPX series steamer provides timed or
continuous mode cooking in a "pressure-less"
compartment. The small physical size of the
steamer offers an efficient way to produce many
foods in small batches. Pressure-less, convection
steam cooking will steam cook fresh foods or will
steam defrost and cook frozen foods providing the
maximum color, flavor and nutritional value with the
least expenditure of energy and labor. The
"pressure-less" cooking compartment allows the
operator to open and close the door, anytime during
a cooking cycle.

Model Designations


VPX3 - 3 pan capacity*

VPX5 - 5 pan capacity*
*based on 2.5 inch pan depth
Exterior Dimensions

VPX3 - 21"w x 25"d x 25" h*

VPX5 - 21"w x 25"d x 31.5" h*
*Includes 4" legs and 2" steam vent height

SPECIFICATIONS

Water Requirements

Use "potable" tap water that meets the following
specifications:
VPX SERIES STEAMERS - GENERAL

GENERAL






Electric

Standard




Special




Page 3 of 20
Hardness of 2-3 grains (34-35ppm)
Total dissolved solids (TDS) less than 60ppm
Ph factor of 7.0 to 7.5
These specifications can easily be obtained
with the use of a properly maintained water
softener.
2.5 gallons to fill holding pan (approximate)
AMPERAGE PER LINE (60HZ)
TOTAL
MODEL
3 PHASE
KW
208V 240V 480V 208V
9.0 std.
25.0
VPX3
3
6.0
-
15.0 std.
41.7
VPX5
3
10.0
-
NOTES: 1. Amperage values in the table are nominal.
Tolerance is +5/-10%.
2. All models are shipped for three phase
connections. If a single phase connection
is needed, the steamer is field convertible.
Requires jumper wire changes at terminal
block. See wiring diagram 7264.
3. Field convertible to a reduced kw output
(2/3 power connection). Requires jumper
wire changes at terminal block
diagram 7264.

TOOLS

Standard set of hand tools
Clear silicone sealant
VOM with an AC current tester (any quality
VOM with a sensitivity of at least 20,000 ohms
per volt can be used)
Temperature meter & thermocouple
Thermal Transfer Compound, Dow Corning
340 P/N 819643-2 or equivalent
NOTE: The additional tools below are required
if replacing heating element assembly.
Torque wrench (in-lb.)
Tile Trowel 3/16" x 5/32" V notch; Grainger
catalog stock number 5LG08 or equivalent
Loctite 271 or equivalent
1
2
2
1 PHASE
240V
21.7
10.9
43.3
37.5
-
-
28.9
25.0
36.1
18.1
72.2
62.5
-
-
48.1
41.7
.
See wiring