General; Installation, Operation And Cleaning; Introduction; Features - Vulcan-Hart C24EO3 Service Manual

C24eo series electric countertop steamers
Hide thumbs Also See for C24EO3:
Table of Contents

Advertisement

C24EO SERIES ELECTRIC COUNTERTOP STEAMERS - GENERAL
INSTALLATION, OPERATION AND
CLEANING
Refer to the Installation & Operation Manual for
specific instructions.

INTRODUCTION

Features

Requires no water or drain line connections
(manual fill & manual drain).
Cast aluminum element block for efficient heat
transfer and distribution.
Field convertible to single phase or three phase
power depending on the supply available.
3.0 gallons maximum holding pan capacity.

Steam Cooking

The C24EO series steamer provides timed or
continuous mode cooking in a pressure-less
compartment. The small physical size of the steamer
offers an efficient way to produce many foods in small
batches. Pressure-less, convection steam cooking will
steam cook fresh foods or will steam defrost and cook
frozen foods providing the maximum color, flavor and
nutritional value with the least expenditure of energy
and labor. The pressureless cooking compartment
allows the operator to open and close the door,
anytime during a cooking cycle.

Model Designations

C24EO3 - 3 pan capacity
C24EO5 - 5 pan capacity
NOTE: based on 2.5 inch pan depth

Exterior Dimensions

C24EO3 - 24" w x 33" d x 19.5" h
C24EO5 - 24" w x 33" d x 26" h

SPECIFICATIONS

A potable water supply does not guarantee that it's
suitable for steam generation. The water supply must
be within the following specifications or a local water
treatment specialist may need to be consulted. If a
water treatment system is installed, it must be properly
maintained.
WATER REQUIREMENTS

GENERAL

Hardness - Less than 3 grains (17.1ppm = 1 grain
of hardness)
Silica - Less than 13 ppm
Total Chloride - Less than 4 ppm
Ph range of - 7.0 to 8.0
Un-dissolved Solids - less then 5 microns
MODEL
C24EO3
C24E05
NOTES:
Standard
Standard set of hand tools
Clear silicone sealant
VOM with an AC current tester (any quality VOM
with a sensitivity of at least 20,000 ohms per volt
can be used)
Temperature meter & thermocouple
Special
Thermal Transfer Compound, Dow Corning 340
Part No. 819643-2 (13.5 oz. tube) or equivalent
for heating element assembly
Thermal Transfer Compound, Dow Corning 340
Part No. 519504 (2 oz. tube) or equivalent for
thermostats
Torque wrench (in.-lb.)
Page 3 of 27
ELECTRIC
AMPERAGE PER LINE
TOTAL
3 PHASE
KW
208
240V 480V 208V 240V
V
8
22.2 19.2
-
12
33.3 28.9 14.4 57.5 50.0
1.
Amperage values in the table are
nominal. Tolerance is +5/-10%.
2.
HC24EO3 - Shipped for 208V 60-50
HZ 3 phase connection. Field
convertible to 240V three phase or
208/240V single phase. See wiring
diagram AI2853.
3.
HC24EO5 - Shipped for 208V or
240V or 480V 60-50 HZ, 3 phase.
208V and 240V models are field
convertible to 1 phase. See wiring
diagram (LINK to AI2852).

TOOLS

1 PHASE
38.5 33.3
F25386 (0415)

Advertisement

Table of Contents
loading

This manual is also suitable for:

C24eo5

Table of Contents