Thermocouple Probe - Vulcan-Hart VG30 Service Manual

Gas braising pans (30 & 40 gallon)
Table of Contents

Advertisement

GAS BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
G.
Verify roller arm position on switch.
1)
Measure the distance from the rear of
the switch body to the center of the
roller. The distance should be 3".
H.
If distance is ok, proceed to step 7.
I.
If distance is not ok, adjust the roller arm
position (as necessary) to obtain the 3"
roller arm dimension.
F25121 (February 2003)
7.
Reverse procedure from step 5 to complete the
installation.
8.
Adjust pan position/down limit switch on switch
mounting bracket as outlined under PAN
POSITION SWITCH ADJUSTMENT in
SERVICE PROCEDURES AND
ADJUSTMENTS.

THERMOCOUPLE PROBE

1.
Access temperature controller as outlined under
TEMPERATURE CONTROLLER .
2.
Disconnect thermocouple lead wires.
3.
Raise the pan to the full tilt position.
4.
Remove insulation cover bracket.
5.
Loosen lock nut and remove threaded probe
from pan.
Page 8 of 32
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Vg40Ml-126847Ml-126848