Up Limit Switch; Lid Switch; Thermocouple Probe - Vulcan-Hart VE30 Service Manual

Electric braising pans (30 & 40 gallon)
Table of Contents

Advertisement

ELECTRIC BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
7.
Reverse procedure from step 5 to complete the
installation.
8.
Adjust pan position/down limit switch on switch
mounting bracket as outlined under PAN
POSITION/DOWN LIMIT SWITCH
ADJUSTMENT in SERVICE PROCEDURES
AND ADJUSTMENTS.

UP LIMIT SWITCH

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove front panel as outlined under
COVERS AND PANELS.
2.
Disconnect lead wires from switch.
3.
Remove switch from mounting bracket.
4.
Reverse procedure to install and check for
proper operation.

LID SWITCH

WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove lid switch cover from lid switch
support bracket.
2.
Remove switch from lid support bracket.
3.
Lift terminal cover off switch body and
disconnect lead wires.
4.
Reverse procedure to install and adjust switch
as outlined under LID SWITCH ADJUSTMENT
in SERVICE PROCEDURES AND
ADJUSTMENTS.

THERMOCOUPLE PROBE

1.
Access temperature controller as outlined under
TEMPERATURE CONTROLLER .
2.
Disconnect thermocouple lead wires.
3.
Raise the pan to the full tilt position.
4.
Remove harness cover.
Page 9 of 32
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
F35410 (May 2003)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ve40

Table of Contents