Pan Position/Down Limit Switch - Vulcan-Hart VE30 Service Manual

Electric braising pans (30 & 40 gallon)
Table of Contents

Advertisement

ELECTRIC BRAISING PANS - REMOVAL AND REPLACEMENT OF PARTS
7.
Check calibration as outlined under
TEMPERATURE CONTROLLER
CALIBRATION.
PAN POSITION/DOWN LIMIT
SWITCH
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT /
TAGOUT PROCEDURES.
1.
Remove front and left side panels as outlined
under COVERS AND PANELS.
2.
Remove strain relief nut from end of strain
relief body and remove pan position/down limit
switch from switch mounting bracket.
LEFT SIDE VIEW SHOWN
3.
Remove cover from switch.
4.
Disconnect lead wires and pull wires thru strain
relief body.
5.
Remove strain relief body from switch.
NOTE: When installing, ensure the o-ring seal is
inserted into the strain relief body (around power
cable) before tightening strain relief nut.
6.
To install:
A.
Position the switch with the head pointing
toward installer and gear cam pointing up.
NOTE: The plunger on the head is spring loaded
and will push the head away from switch body when
the last screw is removed.
B.
Remove screws securing the head to
switch body, rotate 90° clockwise and
tighten screws to secure.
C.
Place switch on its side with the head to
the left and gear cam pointing up.
Page 7 of 32
TOP VIEW SHOWN
F35410 (May 2003)

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ve40

Table of Contents