Total Restaurant Supply - https://totalsupply1.com - Toll Free 1-800-944-9304 - Local 507-288-9454
C24EO SERIES STEAMERS - REMOVAL AND REPLACEMENT OF PARTS
HIGH LIMIT THERMOSTAT
Do not sharply bend and kink, or clamp
down on the capillary tube or damage may occur.
1. Remove right SIDE PANEL.
2. Disconnect lead wires from high limit.
3. Remove thermostat from mounting bracket.
4. Remove screw and heat shield to access
capillary bulb.
5. Loosen screws securing capillary bulb.
2940 Hwy 14 W, Rochester, MN 55901
6. Remove high limit thermostat.
7. Reverse procedure to install and check steamer
NOTE: Do not clamp bulb with excessive force.
1. Remove right SIDE PANEL and REAR PANEL.
2. Disconnect lead wires.
3. Remove low water thermostat.
4. Reverse procedure to install and check steamer
Page 7 of 24
for proper operation.
A. Apply a small amount of thermal transfer
compound between capillary bulb and
heating element assembly.
LOW WATER THERMOSTAT
for proper operation.
A. Apply small amount of thermal transfer
compound to tip of thermostat.
B. Apply Loctite 242 to threads of thermostat.
F25386 (June 2010)