Lift Assist Springs - Vulcan-Hart ERO15 Service Manual

Er series electric fryers with tridelta controls
Table of Contents

Advertisement

ER SERIES ELECTRIC FRYERS - REMOVAL AND REPLACEMENT OF PARTS
NOTE: When installing high limit, route the capillary
tube and center the bulb between the clamps before
tightening.
3.
Remove element assembly clamps. Front
clamps stiffen and secure both elements
together. Rear clamps stiffen each individual
element.
4.
Remove element head cover as outlined under
COVERS AND PANELS.
5.
Disconnect heating element lead wires.
NOTE: Each heating element assembly contains
three individual elements (six lead wire connections
total).
6.
Remove screws from heating element
mounting bracket and remove heating element.
7.
Reverse procedure to install.

LIFT ASSIST SPRINGS

1.
Remove rear door (access cover) as outlined
under COVERS AND PANELS.
2.
Raise heating elements and place 2x4 lumber
under them for support. Heating elements are
to remain upright.
3.
Loosen all eye bolt mounting nuts to release
tension on springs.
Page 13 of 48
WARNING: DISCONNECT THE
ELECTRICAL POWER TO THE
MACHINE AND FOLLOW LOCKOUT
/ TAGOUT PROCEDURES. THERE
MAY BE MULTIPLE CIRCUITS. BE
SURE ALL CIRCUITS ARE
DISCONNECTED.
F35613 ( September 2003)