Removals and Replacements
Replacement
• Slide the power supply into the frame ensuring that the locking
pin
fJ
is engaged
.
• Route the 5-volt sense cable through the center frame cutout to
P5 on the power distribution card
.
• Replace the plate
D
ensuring that the cable is not pinched.
• Connect the ac power cord to AUX2 on the power distribution
contrai box
.
• Replace cable ties as required
.
• Replace the front bezel of the DRB power supply.
• Connect the DRB hand-held unit to the DRB power
supply.
• Connect the power cord and power on the system
.
• Verify correct operation of the
DRB.
lf you have a failure, refer
to "MAP 3000: DRB and Power
Supply"
on page
169.
• lnstall right cover (1006).
• In stai l left cover (1 005)
.
SECTION 3. Removai/Replacement Procedures