1062 Emergency Power Off (Epo) Switch - IBM 7785 Hardware Maintenance

Table of Contents

Advertisement

Removals and Replacements
1062 Emergency Power Off (EPO) Switch
Removal
• Unplug the power cord from the electrical outlet.
• Remove right cover (1 006).
• Remove front cover (1 008).
• Disconnect the EPO cable from the power distribution contrai
box.
• Remove the two cable clamps that secure the cable to the
chassis.
• Remove the screw that secures the EPO ground to the chassis.
• Remove the bracket
Il
and
two
screws that secure the bezel to
the cover.
• Remove the two screws
D
that secure the EPO switch
fJ
to
the bezel.
64