@Simplified illuminance in ambient light mode
Select this display when you measure the brightness
of a continuous light source. The measurement
will be displayed as Ix (Lux) or FC (Foot-candle) as
selected in the custom settings mode (See P 41)
(Note )
llluminance Measurement
( Display in lux)
@The simplified illumination values display the first 3 digits of the measurement values, and is
used as a reference for consistent light amount in photography, video or cinematography
applications. It is not recommended to use for actual exposure values or calibration purposes..
@1 MK" is equivalent to 1 Mired. (See P47)
@The unit of "MK?" is now used based on the International System of Units (SI) The latest unit
is adopted to Prodigi Color C-500R/500.
5-5. Setting the Selected Color Temperature
A target color temperature (Kelvin number) can be set according to your
color balancing needs. After setting, indicated value for either LB/CC filter
number display or LB/CC index display mode will display the filtration
needed to achieve the target color balance. The selected color
temperature is displayed in the upper right hand corner of the LCD screen.
@The selected color temperature will not be displayed and
cannot be changed if the display mode is showing the meas-
ured color temperature or simplified illuminance values.
While pressing the SET K button J, turn the Jog
wheel El to set the selected color temperature.
DIGITAL efik
Measurement
screen
wn BEF hh
LB Index + CC index
14
mDtk
m
SCHE]
cc
FILTER
LB
FILTER
E 224m
Bor
O
Een
SET K Button