Model Number Descriptions
Digit 26 — Controls
2
=
Customer supplied terminal
interface (CSTI)
3
=
CSTI with low temperature
detection
4
=
Tracer® ZN520 controller
5
=
Tracer® ZN520 with time clock
6
=
Tracer® ZN520 with fan status
A
=
Tracer® UC400-B controller
B
=
Tracer® UC400-B with time clock
C
=
Tracer® UC400-B with Air-Fi® WCI
E
=
Symbio™ 400-B controller
F
=
Symbio™ 400-B with time clock
G
=
Symbio™ 400-B with Air-Fi® WCI
N
=
CSTI fan status
P
=
Thermostat
Digit 27 — Unit- or Wall-Mounted
Controls
0
=
None
1
=
Unit-mounted
2
=
Wall-mounted
3
=
Combined unit-mounted and wall-
mounted sensor
4
=
Wireless zone sensor
Digit 28 — Internal or External Set
Point
0
=
None
2
=
External
3
=
Digital display
Digit 29 — Timed Override
0
=
No timed override
1
=
Yes, Timed override
Digit 30 — Exhaust Control
A
=
No exhaust with 3-speed supply
fan
B
=
Exhaust control with 2-speed
supply fan
Digit 31 — Programming Options
0
=
None
1
=
Humidity sensor programming
2
=
CO2 sensor programming
3
=
Air-Fi® Humidity Sensor and CO
4
=
Air-Fi® Humidity Sensor
5
=
Air-Fi® CO
2
Digit 32 — Depth
A
=
16.63 in. standard depth
B
=
21.25 in. depth with baffle
C
=
21.25 in. depth with full sheet metal
back with baffle
D
=
21.25 in. depth with 25 in. high
falseback
E
=
221.25 in. depth with 26 in. high
falseback
F
=
21.25 in. depth with 27 in. high
falseback
G
=
21.25 in. depth with 28 in. high
falseback
H
=
21.25 in. depth with 29 in. high
falseback
J
=
21.25 in. depth without baffle
6
Digit 33 — End Covers
0
=
No decorative end covers
1
=
16.63 in. depth without cutout
2
=
16.63 in. depth with standard
cutout
3
=
16.63 in. depth with extended
cutout
4
=
21.25 in. depth without cutout
2
=
21.25 in. depth with standard
cutout
2
=
21.25 in. depth with extended
cutout
Digit 34 — Front Panel or Access
Panel
1
=
Standard front panel
2
=
Insulated front panel
Digit 35 — Sub-base
0
=
No sub-base
1
=
2 in. sub-base
4
=
4 in. sub-base
6
=
6 in. sub-base
Digit 36 — Piping Package
0
=
None
4
=
Basic -ball valve supply and return
5
=
Basic - ball valve supply and
manual circuit setter return
6
=
Deluxe - ball valve supply and
manual circuit setter return
7
=
Deluxe - ball valve supply and
return with auto flow
Digit 37 — Cooling/Changeover
Auto Flow GPM
0
=
None
A
=
4.0
B
=
4.5
C
=
5.0
D
=
6.0
E
=
6.5
F
=
7.0
G
=
8.0
Digit 38 — Heating Auto Flow GPM
0
=
None
2
A
=
1.0
B
=
1.5
C
=
2.0
D
=
2.5
E
=
3.0
F
=
3.5
G
=
4.0
H
=
4.5
J
=
5.0
K
=
6.0
Digit 39 — Auxiliary Drain Pan
Y
=
Yes, auxiliary drain pan
N
=
No auxiliary drain pan
Digit 40 — Crossover Piping
0
=
No crossover piping
1
=
Internal crossover
2
=
External 1 3/8 in. crossover piping
3
=
External 2 1/8 in. crossover piping
Digit 41 — Filter
1
=
Standard throwaway filter
2
=
Merv 8 filter
3
=
Merv 13 filter
Digit 42 — Cabinet Color
1
=
Standard deluxe beige
2
=
Cameo white
3
=
Soft dove
4
=
Stone gray
5
=
Driftwood gray
UV-SVX005G-EN