LOADING FACTORY DEFAULTS

To load the factory defaults, enter the program mode using the procedure on page 24, then
type [9]-[1]-[0]-[#]. The keypad will beep 3 times to indicate that loading is in progress. The
loading takes about 6 seconds.

ENROLLING MODULES AND KEYPADS

For supervision purposes, the presence of all keypads, zone expanders, wireless receivers, and
any other modules connected to the data terminal can automatically be found and stored in
the NX-8's memory. This allows the control panel to supervise these modules. To enroll the
modules, enter the program mode for the NX-8 control panel as described above. If necessary,
go on to program the rest of the control panel and the devices. When you exit from program
mode, the control panel will automatically enroll the devices. The enrolling process takes
about 12 seconds, during which time the "Service" LED will light up. If a module has been
enrolled but it is not detected by the control, the "Service" LED will light up.
PROGRAMMING EXAMPLE (Numerical data)
Zone 1 LED = 1
Zone 4 LED = 8
Data = 9
To cha
nge data
in a se
gment,
enter the data
followed by [*]
Enters the previous
programming "location"
NX-8-EUR Installation manual
Zone 2 LED = 2
Zone 7 LED = 64
Data = 66
Returns to
the "loca
tion"
just programmed
Page 28
Pressing [#] will exit
a location without
changing the data
in the current
segment