CONFIGURATION GROUP 1 ALARM CODE
111
73
CONFIGURATION GROUP 1 CHARACTERISTIC SELECT
1
Fire (enable for fire zone)
2
24 Hour (enable for non-fire 24 hour zone)
3
Keyswitch zone
4
Follower (enable for burglary zones that are
instant during non-entry times)
1
Keypad audible on alarm
2
Yelping siren on alarm
3
Steady siren on alarm
4
Chime
1
Fast Loop Response
2
Double End of Line Tamper zone
3
Trouble zone (Fire and Day zone)
4
Cross Zone
1
Zone activity monitor
2
End of line resistor defeat
3
Zone acts as request to exit input
4
Zone acts as acces control zone
1-8
Reserved
THE DEFAULTS LISTED IN THE ODD-NUMBERED LOCATIONS BELOW REPRESENT THE FIVE SEGMENTS OF EACH OF
THOSE LOCATIONS. USE THE FIVE SEGMENT CHARTS FROM LOCATION 111 TO UNDERSTAND THESE DEFAULTS.
112
74
CONFIGURATION GROUP 2 ALARM EVENT CODE
113
74
CONFIGURATION GROUP 2 CHARACTERISTIC SELECT
114
74
CONFIGURATION GROUP 3 ALARM EVENT CODE
115
74
CONFIGURATION GROUP 3 CHARACTERISTIC SELECT
116
74
CONFIGURATION GROUP 4 ALARM EVENT CODE
117
75
CONFIGURATION GROUP 4 CHARACTERISTIC SELECT
118
75
CONFIGURATION GROUP 5 ALARM EVENT CODE
119
75
CONFIGURATION GROUP 5 CHARACTERISTIC SELECT
120
75
CONFIGURATION GROUP 6 ALARM EVENT CODE
121
75
CONFIGURATION GROUP 6 CHARACTERISTIC SELECT
122
75
CONFIGURATION GROUP 7 ALARM EVENT CODE
123
75
CONFIGURATION GROUP 7 CHARACTERISTIC SELECT
124
76
CONFIGURATION GROUP 8 ALARM EVENT CODE
125
76
CONFIGURATION GROUP 8 CHARACTERISTIC SELECT
126
76
CONFIGURATION GROUP 9 ALARM EVENT CODE
127
76
CONFIGURATION GROUP 9 CHARACTERISTIC SELECT
128
76
CONFIGURATION GROUP 10 ALARM EVENT CODE
129
76
CONFIGURATION GROUP 10 CHARACTERISTIC SELECT
130
76
CONFIGURATION GROUP 11 ALARM EVENT CODE
131
77
CONFIGURATION GROUP 11 CHARACTERISTIC SELECT
132
77
CONFIGURATION GROUP 12 ALARM EVENT CODE
133
77
CONFIGURATION GROUP 12 CHARACTERISTIC SELECT
134
77
CONFIGURATION GROUP 13 ALARM EVENT CODE
135
77
CONFIGURATION GROUP 13 CHARACTERISTIC SELECT
136
77
CONFIGURATION GROUP 14 ALARM EVENT CODE
137
77
CONFIGURATION GROUP 14 CHARACTERISTIC SELECT
NX-8-EUR Installation manual
Segment 1 (Circle Numbers To Program)
5
Delay 1 zone (enable to follow Timer 1 Entry/Exit times)
6
Delay 2 zone (enable to follow Timer 1 Entry / Exit times)
7
Interior (Enable for auto bypass or stay arming)
8
Local Only (enable if zone is not to be reported)
Segment 2 (Circle Numbers To Program)
5
Bypassable
6
Group Shunt
7
Force armable
8
Entry Guard
Segment 3 (Circle Numbers To Program)
5
Dialer Delay zone
6
Swinger zone
7
Restore reporting
8
Listen-In
Segment 4 (Circle Numbers To Program)
5
Reserved
6
Reserved
7
Reserved
8
Reserved
Segment 5 (Circle Numbers To Program)
Page 100
4
2
2-125-278
7
5-125-25678
5
45-125-25678
5
457-125-25678
4
0-125-25678
0
2-5-278
1
1-13-378
7
6-125-25678
13
24-12-78
3
3-0-2
5
457-125-245678
4
0-1258-25678
7
5-1256-25678