GE NetworX NX-8-EUR Installation Manual page 74

Table of Contents

Advertisement

LOCATION 106 - PARTITION 7 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 106 is used to enter the entry and exit times in seconds. There are 2 separate entry
and exit times. Valid entries are 10-255 seconds. If all the segments are "0", the entry and exit
times for partition 1 will be used.
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
LOCATION 107 - ACCOUNT CODE FOR PARTITION 8 (6 segments, numerical data)
The account code that is sent when reporting partition 8 is programmed in location 107. If
location 107 is left unprogrammed (all "10") then the account code corresponding to the
phone number that is dialled will be used. If the account code is less than six digits, program a
"10" in the segment immediately after the last digit of the account code. If the account code is
6 digits long, program all 6 segments.
LOCATION 108 - PARTITION 8 FEATURE AND REPORTING SELECTIONS (5 segments, feature selection data)
Location 108 is used to enable certain features that the user can access or see from the
keypad of the system. In addition, certain communicator reports are enabled in this location.
Each of these features can be enabled by partition. This location contains 5 segments, with
eight possible features per segment. Refer to location 23 for the feature selections. If all the
segments are blank (nothing enabled), the features for partition 1 will be used.
LOCATION 109 - PARTITION 8 ENTRY EXIT TIMERS (6 segments, numerical data)
Location 109 is used to enter the entry and exit times in seconds. There are 2 separate entry
and exit times. Valid entries are 10-255 seconds. If all the segments are "0", the entry and exit
times for partition 1 will be used.
Segment 1
Segment 2
Segment 3
Segment 4
Segment 5
Segment 6
NX-8-EUR Installation manual
Entry time 1
Entry time that will be used when a delay 1 zone type
initiates an entry delay
Exit time 1
Exit time that will be used for all zones designated as
delay 1
Entry time 2
Entry time that will be used when a delay 2 zone type
initiates an entry delay
Exit time 2
Exit time that will be used for all zones designated as
delay 2
Reserved
Reserved
Entry time 1
Entry time that will be used when a delay 1 zone type
initiates an entry delay
Exit time 1
Exit time that will be used for all zones designated as
delay 1
Entry time 2
Entry time that will be used when a delay 2 zone type
initiates an entry delay
Exit time 2
Exit time that will be used for all zones designated as
delay 2
Reserved
Reserved
Page 74