Zone configurations and partition selection

DEFAULT ZONE CONFIGURATIONS
Zones can be programmed to be one of thirty different zone configurations (zone types). The
default zone configurations are listed below. Programming locations 110-169 can customise
all zone configurations.
DATA
R conf.
1
1
DAY ZONE
Instant when system is armed; trouble zone when system is disarmed. A day zone will only
work if programmed for single end-of-line resistor.
2
2
24 HOUR AUDIBLE
Creates an instant yelping siren alarm regardless of the arming state of the control panel.
This zone type is not abortable. This zone can be bypassed.
3
2
ENTRY/EXIT DELAY 1
A trip will start entry delay 1. Absence of a trip during the exit delay will enable the Automatic
Bypass or Instant mode, if so programmed.
4
2
FOLLOWER (WITH AUTO- BYPASS DISABLED)
This zone will be instant when the system is armed and no entry or exit delays are being
timed. It is delayed during entry and exit delay times. This zone will not bypass automatically,
even if enabled in segment 1 of location 23.
INTERIOR FOLLOWER (WITH AUTO- BYPASS ENABLED)
5
2
This zone will be instant when the system is armed and no entry or exit delay is being timed.
It is delayed during entry and exit delay times. This zone will bypass automatically, if enabled
in segment 1 of location 23.
6
2
INSTANT
This zone creates an instant alarm whenever it is tripped and the armed LED is on.
7
2
24 HOUR SILENT
Creates an instant silent alarm regardless of the arming state of the control panel. It will not
display on the keypad. This zone is not abortable, but can be bypassed.
8
1
FIRE
This zone will light up the fire LED and sound the steady siren each time the zone is shorted.
It will also rapidly flash the fire LED, indicating trouble if the zone is open. This zone cannot be
bypassed.
ENTRY/EXIT DELAY 2
9
2
A trip will start entry delay 2. Absence of a trip during the exit delay will enable the automatic
bypass or instant mode, if so programmed.
24 HOUR AUDIBLE SUPERVISED
10
1
Creates an instant audible alarm, regardless of the arming state of the control panel. It will
display on the keypad (e.g. flashing zone LED's, and changed READY LED). This zone is not
abortable and cannot be bypassed.
11
2
MOMENTARY KEYSWITCH ZONE
This zone type will arm and disarm the partition or partitions of the control panel where it is
resident, every time the zone is shorted. Keyswitch arming will report as user 99. This zone
type can only belong to 1 partition.
NX-8-EUR Installation manual
DESCRIPTION OF DEFAULT CONFIGURATION
Page 47
02/07/06