LOCATION 112 - CONFIGURATION GROUP 2 ALARM EVENT CODE (1 segment, numerical data)
Location 112 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).
LOCATION 113 - CONFIGURATION GROUP 2 CHARACTERISTIC SELECT (5 segments, feature selection data)
Use the "Configuration Group Characteristic Selections" described in Location 111.
LOCATION 114 - CONFIGURATION GROUP 3 ALARM EVENT CODE (1 segment, numerical data)
Location 114 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm.
This location is not used for slow speed formats (like 4+2 and 3+1). This location may also
contain the alarm report code for the Robofon format (value 00-99).
LOCATION 115 - CONFIGURATION GROUP 3 CHARACTERISTIC SELECT (5 segments, feature selection data)
Use the "Configuration Group Characteristic Selections" described in Location 111.
LOCATION 116 - CONFIGURATION GROUP 4 ALARM EVENT CODE (1 segment, numerical data)
Location 116 contains the event code that is sent for a Contact ID or SIA report. The desired
event code should be chosen from the list on pages 121-122. The zone ID will be the zone that
is in alarm. This location is not used for slow speed formats (like 4+2 and 3+1). This location
may also contain the alarm report code for the Robofon format (value 00-99).
NX-8-EUR Installation manual
1 =
On: enables zone activity monitor
2 =
On: enables end of line resistor defeat on non-fire/non-keyswitch
zones
3 =
On : enables zone to act as request to exit input / disables for alarm
activation
4 =
On : enables zone to act as access entry point (Door Shunt)(*)
5 =
Reserved
6 =
Reserved
7 =
Reserved
8 =
Reserved
1-8
Reserved
Refer to NX-17xx door control installer manual. Do not enable this segment unless
configured with Door Control.