GE NetworX NX-8-EUR Installation Manual page 12

Table of Contents

Advertisement

Program code
The factory default for the "Go To Program" code is [9]-[7]-[1]-[3] when using a 4-digit code; or,
if the 6-digit option is used, the default is [9]-[7]-[1]-[3]-[0]-[0]. The program code can also be
used as an arm/disarm code. If it is used as an arm/disarm code, and if open/close reports are
sent, the user code will be 255 (see location 43).
Quick arm feature
The NX-8 has a single-button "Quick Arm" feature which can be used to arm the system by
pressing the [Exit] key or the [Stay] key on the keypad. If closing reports are sent, the user code
will be 98 (see location 23 segment 1).
Recent closing
If this option is enabled, the NX-8 will send a "Recent Closing Report" to the central station if
an alarm occurs within 5 minutes after the panel is armed. The user number that was used to
arm the system will also be sent (see location 23 segment 3).
Re-exit
The NX-8 can restart the exit delay for a quick exit without the need to disarm the system; this
is done by pressing the [Exit] key while the system is still armed (= after exit delay has expired).
The re-exit is also logged (see location 23 segment 1).
Shutdown
This mode will cause the keypads to extinguish all LED's, except the "Power" LED, and to refuse
keypresses (see location 21).
Siren blast for arming
The NX-8 can be programmed to give a one-second siren blast when the panel is armed, at
the end of the exit delay, or when the central station receiver acknowledges the closing report.
It can also give one blast for remote (keyswitch) arming, and two blasts for remote disarming
(see location 37 segment 1).
Siren supervision
The NX-8 has a "Siren Supervision" circuit that will constantly monitor the siren on the NX-8; it
can also be programmed to report if the wires are cut (see location 37 segment 3).
Silent exit option
The exit delay can be silenced by pressing [*]-[Exit] before arming the control panel, or when
using the re-exit feature. The exit delay can also be silenced permanently in all partitions (see
location 37 segment 5).
Start/end programming and end downloading
A report can be sent when local programming is started and ended. A report can also be sent
when a download session ends (see location 37 segment 4).
Swinger shutdown
This feature allows one or more zones to be bypassed automatically after a specified number
of alarms (from 0 to 255). If immediate restore is enabled in location 37, the alarms (and
restores, if this option is enabled) will be sent as they occur. If immediate restore is not
enabled, a second or subsequent alarm will not be sent until the siren times out (see location
37 segment 2 and location 38).
Telephone line monitor
The NX-8 has a telephone line monitor which monitors the voltage and current of the
telephone line, in order to detect a faulty phone line. This condition can also be reported to the
central station. If the report is enabled, only the telephone line restore will be reported. A
telephone line cut is always logged (see locations 37 segment 3, location 39 and location 40
segment 5).