Fujitsu PRIMERGY GX2560 M7 Upgrade And Maintenance Manual page 314

Table of Contents

Advertisement

Appendix A
Drive activity indicator (2)
Status
flashing green
NIC indicator (3) (4)
Status
flashing green
Information indicator (5)
Status
solid red on
flashing red at 1 Hz
flashing red at
0.25 Hz
flashing red at 10 Hz
flashing red at 10 Hz
and the rear UID LED
is flashing blue at
10 Hz
solid blue on
flashing blue at 1 Hz
flashing blue at 2 Hz
and BMC Heartbeat
LED on the
motherboard is green
flashing blue at 4 Hz
flashing blue at 10 Hz BIOS/BMC is recovering or updating.
flashing blue
314
Description
Storage drive activity.
Description
Network activity.
Description
An overheating condition has occurred.
Fan failure, check for an inoperative fan.
Power failure, check for a non-operational PSU.
CPLD recovery mode error.
CPLD recovery or update is in progress.
UID has been activated by switch.
UID has been activated using the BMC.
BMC is resetting.
BMC is setting factory defaults.
UID has been activated remotely to locate the server.
Upgrade and Maintenance Manual