Installation Of The Spare Transmitter; Parameter Setting; Relevant Settings And Parameter Storage; Setting Methods - Siemens SITRANS FC720 Operating Instructions Manual

Coriolis c
Table of Contents

Advertisement

FC7x0
Transmitter replacement

19.2 Installation of the Spare transmitter

For the installation of the Spare transmitter, please refer to chapter Transmitter
installation [} 96].

19.3 Parameter setting

19.3.1 Relevant settings and parameter storage

The SITRANS FC transmitter has four kinds of relevant parameters which must be
Relevant
adjusted to ensure a proper operation of the flowmeter:
settings
▪ System relevant parameters - a device can be identified in one of the three
▪ sensor related parameters (liquid or gas select, mass flow- or volume flow unit,
▪ sensor specific parameters (SK20, KD, fl20)
▪ customer specific parameters (lowcut and URV)
System relevant parameters are stored on the microSD card of the Spare transmitter in
Storage
the file "Factory.PAR".
location of
parameters
Sensor relevant parameters and sensor specific parameters are available on the
microSD card of the defective transmitter in the file "Factory.PAR".
The default setting of sensor specific and sensor related parameters in the spare
Delivered
transmitter is based on SITRANS FCS700 DN100 made of stainless steel for standard
parameter setting
process fluid temperature range.
Order Code: 7ME4479-xxxxx-xxxx-Z

19.3.2 Setting methods

Configuring the Spare transmitter with the sensor settings always needs a backup file of
the defective transmitter.
▪ If the microSD card from the defective transmitter is available, insert it into the Spare
The factory backup file of the defective transmitter is stored on the microSD in the
directory "SIEMENS" attached to the defect SITRANS FC at delivery time. Please
make sure to use a differing file name in case of coping to microSD of the Spare
transmitter
The method to set up the Spare transmitter properly depends on the following order code
positions of the defective SITRANS FC in comparison to the Spare Transmitter:
Inputs and Outputs
1. Position -Z: Communication type and I/O Configuration
EXAMPLE: E06+F13 = HART with I/O1 – 4 defined (defined acc. to OI)
160 / 180
following ways:
– device identifier (ID) – fixed value by manufacturer
– device (HART) tag
– address (HART, Modbus, PROFIBUS PA)
temperature unit...)
transmitter.
7 M E 4 4 x
-
7
5 6
A5E52748387-AA, 2023/09
-
8 9 10 11
12
13 14 15 16
Installation of the Spare transmitter
-
Z

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sitrans fc740

Table of Contents