Installing/Mounting; Introduction; Strong Vibrations; Transmitter Installation - Siemens SITRANS FC430 Operating Instructions Manual

Coriolis flowmeters with hart
Hide thumbs Also See for SITRANS FC430:
Table of Contents

Advertisement

Installing/mounting

4.1

Introduction

SITRANS F flowmeters with minimum IP67/NEMA 4X enclosure rating are suitable for indoor
and outdoor installations.
● Make sure that specifications for rated process pressure (PS) and media temperature
(TS) plus ambient temperature that are indicated on the device nameplate / label will not
be exceeded.
4.2

Strong vibrations

Damage to device
In plants with strong vibrations, mount the transmitter in a low vibration environment away
from the sensor.
4.3

Transmitter installation

This chapter describes how to install the transmitter on a wall or pipe (remote configurations
only). The chapter further describes how to turn the transmitter or the local display in order to
optimize the viewing angle.
The following installation steps must be carried out:
1. Install the mounting bracket (Page 42) on a wall or pipe.
2. Install the transmitter on the mounting bracket (Page 43).
3. Turn the transmitter (Page 43) and/or turn the local display (Page 45) (optional).
Aggressive atmospheres
Damage to device through penetration of aggressive vapors.
• Ensure that the device is suitable for the application.
FC430 with HART
Operating Instructions, 05/2015, A5E03361511-AF
WARNING
Installation in hazardous location
Special requirements apply to the location and installation of the device. See Installation
in hazardous locations (Page 23).
CAUTION