3
FLUSH OUT SUPPLY LINES
1. Remove STOP VALVE COVER (1) from STOP
VALVE (2).
2. Open STOP VALVE (2) with a flat blade screwdriver.
3. Turn on water supply to flush line of any debris or
sediment.
4. Close STOP VALVE (2) and replace STOP VALVE
COVER (1).
B
4a
INSTALL VACUUM BREAKER TUBE: APPLICABLE FOR STANDARD CERAMICS
Note: Step 4a is only applicable if using standard
ceramics. If using IoT Ceramics, skip to step 4b.
1. Insert VACUUM BREAKER TUBE (1) through
HEX NUT (4), FLUSH VALVE BOTTOM COVER
(2), and SPUD COVER (3).
2.
Thread SPUD COVER (3) on to the toilet base.
Note: Ensure that the O-ring is properly seated in the
base of HEX NUT (4).
C
2
REMOVE COVER
2
COUNTER-CLOCKWISE
OPENS STOP VALVE
CLOCKWISE CLOSES
STOP VALVE
4
2
1
3
1