MAINTENANCE: REPLACE BATTERY
1. Loosen SET SCREW (1) with 2.5mm Hex Wrench (2) in back of FLUSH VALVE COVER (3).
2. Rotate COVER (3) to the right and pull off.
3. Turn COVER (3) over and disconnect the SENSOR (4) from the BATTERY (5).
5. Remove old BATTERY (5) and replace with the new battery.
7. Connect BATTERY (5) to SENSOR (4).
1
16
REPLACE BACK-UP BATTERY KIT FOR AC VERSION
Remove old back-up battery by disconnecting the
1.
two wires.
Install new kit by connecting it to the two wires.